We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Fragmented Red Blood Cell Measurement Automated

By LabMedica International staff writers
Posted on 02 Jul 2012
Print article
Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
The laboratory diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult.

The detection of schistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of schistocytes is still problematic with wide inter-observer variations.

Hematologists at the University Hospital (Nancy, France) conducted studies comparing automated and microscopic counts of Fragmented Red Blood Cells (FRC) and schistocytes. The data came from the day-to-day analysis of more than 90,000 peripheral blood (PB) samples for 10 years in four centers. More than 900 patients were examined because of a clinical suspicion of TMA and 17 samples were derived from preterm newborns who were supposed to give the highest FRC counts among nonpathologic samples.

FRC were counted by automated direct measurement using the two automated analyzers (ABCC): the ADVIA 120 analyzer (Siemens; Tarrytown, NY, USA) and the XE-2100 analyzer (Sysmex; Kobe, Japan). Schistocyte counting was carried out from May-Grünwald-Giemsa-stained PB smears. The reference range for FRC was less than 0.3% for the ADVIA and less than 0.5% for the Sysmex XE-2100.

The correlation coefficient for Siemens devices was around 0.7. The main problem resulted from an overestimation of FRC as compared to schistocytes from 0.4% to 0.5% for a count of schistocyte ranging from 0% to 1.5%. Conversely, the scientists observed an underestimation of FRC as compared to schistocytes subsequent to this 1.5% threshold. For the Sysmex XE-2100 counter, the overestimation of the FRC was more pronounced, at less 0.8%, and increased slightly with high schistocyte percentages. The presence of FRC below a threshold determined at 1% for both automated analyzers had a negative predictive value (PV) close to 100% to exclude the presence of schistocyte on the blood smear, but in relationship with a poor positive PV value.

The authors concluded that that systematic quantification of FRC might improve the laboratorians' ability to exclude samples with schistocytes. This should be especially useful among patients in whom TMA diagnosis is suspected. However, several limitations deserve consideration such as few false-negative FRC counts in a context of macrocytosis, great lack of specificity. Hence, a PB smear examination was still advised for the validation of the count if needed. The study was published on June 14, 2012, in the International Journal of Laboratory Hematology.

Related Links:

University Hospital
Siemens
Sysmex


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.