Proteinuria Determined by Automated Analyzer

By LabMedica International staff writers
Posted on 03 Jul 2012
Print article
A rapid, accurate, and cost-effective method for their detection of protein in urine has been developed for the autoanalyzer.

The method is a two-reagent system consists of a buffer solution and surfactants, and a second one consists of a dye solution of Erythrosin B being added to a urine sample, and the dye bound protein is measured by a spectrophotometer.

At the Juntendo University (Tokyo, Japan) nephrologists enrolled 70 outpatients who were screened for proteinuria by the dipstick test. Spot urine samples from the patients and 79 healthy volunteers were examined. Urine samples were stored at -80 °C. A solution containing a buffer agent with a pH 2.3 and surfactants and a solution of Erythrosin B are added to each urine sample. After letting the mixture stand for five minutes at 37 °C, the dye-bound protein is measured by a spectrophotometer at 546 nm using an automated analyzer.

The calibration curve was linear with human serum albumin concentration in the range of 2.4-200 mg/L. The detection limit, 2.4 mg/L was superior to conventional dye-binding methods by one order of magnitude and comparable to the turbidimetric immunoassay (TIA), which is quite expensive. There was an excellent correlation between the results given by the Erythrosin B (Wako Pure Chemical Industries Ltd., Tokyo, Japan) method and those by the TIA.

The authors concluded that the method is equal to the dipstick test in terms of time and cost savings. The reaction was completed within 5 minutes at 37 °C after mixing the test solution, and could be coupled with the 7170S automated analyzer (Hitachi, Tokyo, Japan) for rapid detection. The method was capable of determining actual samples without being influenced by foreign substances in urine such as urea, creatinine, and glucose. This method is sufficiently sensitive for the detection of trace proteinuria in early-stage of chronic kidney disease, and is directly applicable to actual samples. The study was published in the July 2012 issue of the journal Clinica Chimica Acta.

Related Links:

Juntendo University
Wako Pure Chemical Industries Ltd.
Hitachi



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.