Continuous Glucose Monitoring Sensors Compared for Effectiveness

By LabMedica International staff writers
Posted on 01 Oct 2014
Print article
Image: Two popular continuous glucose monitoring (CGM) sensors compared (Photo courtesy of Broken Pancreas).
Image: Two popular continuous glucose monitoring (CGM) sensors compared (Photo courtesy of Broken Pancreas).
A continuous glucose monitor, a tool used in optimizing glycemic control in patients with type 1 diabetes, is a subcutaneous tissue sensor that provides an interstitial fluid glucose measurement every one to five minutes.

The simultaneous use of two popular continuous glucose monitoring (CGM) sensors revealed clear differences in their accuracy and in patient-rated treatment experiences, including ease of use, feelings of safety, and willingness to use the system in daily life.

Scientists at the University of Gothenburg (Sweden) working with their North American colleagues enrolled 38 patients who met the inclusion criteria for the study. The mean age was 50 years, 66% were men, and mean diabetes duration was 22.9 years. The mean HbA1c level was 58.9 mmol/mol or 7.5%. Patients were educated on how to use the CGM sensors, and the sensors were calibrated. All participants were educated on use of the HemoCue (Ängelholm, Sweden) analyzer and cuvettes and were advised to measure capillary glucose values six to 10 times per day.

The 38 ambulatory patients with type 1 diabetes used the Dexcom G4 PLATINUM (San Diego, CA, USA) and the Enlite Guardian REAL-Time System (Medtronic MiniMed, Inc.; Northridge, CA, USA) CGM sensors simultaneously for a minimum of four and maximum of six days. The mean absolute relative difference (MARD) in blood glucose for the Dexcom G4 was significantly lower (13.9%) than for the Enlite sensor (17.8%) among a total of 1,012 sets of measurements. For glucose levels in the hypoglycemic range of less than 4.0 mmol/L, the MARD for the Dexcom G4 was 20.0% compared with 34.7% for the Enlite. More patients rated their experience with the Dexcom G4 as positive and preferred to use it in their daily lives.

The authors concluded that the Dexcom G4 CGM system showed greater accuracy than the Enlite system, and patients had a significantly more positive treatment experience. The findings indicate that the Dexcom G4 is more optimal when dosing insulin, when taking other treatment actions, and in avoiding hypoglycemia. The results also indicate that the Dexcom G4 may make it possible for more patients to wear a CGM device for a longer period of time. These findings should be considered by treatment providers when recommending suitable CGM systems and evaluating ongoing therapies. The study was published on September 18, 2014, in the journal Diabetes Technology & Therapeutics.

Related Links:

University of Gothenburg
HemoCue
Dexcom


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.