Childhood Hereditary Spherocytosis Confirmed by Hematology Analyzer

By LabMedica International staff writers
Posted on 25 Feb 2015
Print article
Image: The CELL-DYN Sapphire hematology analyzer (Photo courtesy of Abbott Diagnostics).
Image: The CELL-DYN Sapphire hematology analyzer (Photo courtesy of Abbott Diagnostics).
The hallmark of hereditary spherocytosis (HS) is a decreased surface area-to-volume ratio of the erythrocytes (RBC), resulting in the characteristic spherocyte form and in a blood film, spherocytes have a smaller diameter than normal RBC and are hyperchromic.


The flow cytometric eosin-5′-maleimide test (EMA) is highly sensitive and specific for HS as a confirmatory method and the utility of hyperchromic erythrocytes in HS screening and evaluation of the EMA test performed on a hematology analyzer was compared with the reference method.

Hematologists at Our Lady's Children's Hospital (Crumlin, Dublin, Ireland) analyzed blood samples from 740 pediatric patients presenting at their institution in the reticulocyte mode of the CELL-DYN Sapphire hematology analyzer (Abbott Diagnostics; Wiesbaden-Delkenheim, Germany) to obtain hyperchromic erythrocyte counts. The EMA test used as a reference for the laboratory diagnosis of HS was performed on a FACSCanto II flow cytometer (Becton Dickinson; San Jose, CA, USA).

Hyperchromic erythrocytes were the highest in patients with HS (median 11.5%; range 5.1 to 29.2%). Patients with autoimmune hemolytic disease had significantly less hyperchromic erythrocytes (median 4.9%; range 0.0 to 18.3%). Hyperchromic erythrocytes showed a high area under the receiver operating characteristic (ROC) curve of 0.972. At 4.9% cut-off, hyperchromic erythrocytes detected HS with 96.4% sensitivity and 99.1% specificity. The EMA test on CELL-DYN Sapphire correlated strongly with the reference test and had identical diagnostic power. Stability studies with blood from HS patients showed a significant decrease in hyperchromic erythrocytes after six hours of storage.

The authors concluded that measurement of hyperchromic erythrocytes is highly sensitive and specific for detecting HS and can be used for rapid and inexpensive screening. If required, the EMA test can be performed on the CELL-DYN Sapphire or a standard flow cytometer for confirmation of HS. The study was published in the February 2015 issue of the International Journal of Laboratory Hematology.

Related Links:

Our Lady's Children's Hospital 
Abbott Diagnostics 
Becton Dickinson


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.