Microfluidic Chip Developed For Ultrasensitive Glucose Detection

By LabMedica International staff writers
Posted on 18 May 2016
Print article
Image: The lab-on-a-chip device integrates a fiber optic biosensor with a microfluidic chip and detects glucose levels from droplets of sweat. It is shown here next to a Hong Kong dollar, which is the same size as the USD coin (Photo courtesy of Dr. A. Ping Zhang).
Image: The lab-on-a-chip device integrates a fiber optic biosensor with a microfluidic chip and detects glucose levels from droplets of sweat. It is shown here next to a Hong Kong dollar, which is the same size as the USD coin (Photo courtesy of Dr. A. Ping Zhang).
Highly sensitive and rapid detection of blood glucose is a diagnostic necessity in medicine as, for instance, lack of insulin and too much blood sugar are two main causes of diabetes, both of which can be detected by measuring blood glucose.

Fiber optics and microfluidics have been used to develop a cheap, ultra-sensitive lab-on-a-chip device that can quickly measure glucose in just a drop of sweat. The technology behind it belongs to a new field called "optofluidics" that brings together photonic sensing (using the properties of light to detect chemicals) and microfluidics (precise control of tiny amounts of fluid along microchannels).

Scientists at the Hong Kong Polytechnic University (Kowloon, Hong Kong SAR, China) and their colleagues combined a new fiber optic biosensor with a microfluidic chip to create an interference-free optofluidic device for ultra-sensitive detection of glucose levels. The fiber optic sensor they created is very sensitive to changes in the refractive index of the material that surrounds it. To transform it into a glucose monitor, the team used a film of glucose oxidase as a sensing material as it reacts with glucose in solution.

To both support the sensing film and further enhance the signal, the team incorporated layers of two other materials - polyethylenimine (PEI) and polyacrylic acid (PAA), into the sensor. The result was several layers of PEI/PAA, with a top layer of glucose oxidase that was then embedded in the microchannel of the chip. After running several tests, the investigators found the fiber optic sensor was very sensitive on its own and can detect glucose oxidase concentrations as low as 1 nM, but after they integrated it into the microfluidic chip, the sensor's performance remarkably further improved. The sensor improved not only in detection range, but also in response time, which shortened from six minutes to 70 seconds.

A. Ping Zhang, PhD, an Assistant Professor and co-author of the study said, “Photonic approaches are seen as one of the most promising techniques for ultra-sensitive sensing, and when you integrate photonics with the tiny platform that microfluidic chips offer, you can make a small lab-on-a-chip analysis system for fast and reliable results.” The study was published on April 28, 2016, in the journal Biomedical Optics Express.

Related Links:
Hong Kong Polytechnic University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.