Serological Assays Define Extent of Legionnaires’ Disease Outbreak

By LabMedica International staff writers
Posted on 29 Apr 2015
Print article
The DSX Automated System for enzyme-linked immunosorbent assays
The DSX Automated System for enzyme-linked immunosorbent assays (Photo courtesy of Dynex Technologies)
Microbiological diagnosis of Legionnaires’ disease (LD) during acute illness is based on culture, polymerase chain reaction (PCR) of respiratory samples, and/or detection of Legionella antigen in urine.

The isolation of Legionella spp. by culture is considered the gold standard for diagnosing LD, but the sensitivity is low, and the urinary antigen test (UAT) has become the most performed test in diagnosing LD because of its easy performance and rapidity.

Scientists at the Ostfold Hospital Trust (Sarpsborg, Norway) investigated a long-distance outbreak of LD caused by Legionella pneumophila serogroup 1 that occurred in south-east Norway. The initial outbreak investigation without serology identified 56 laboratory-confirmed LD cases of whom 10 died. However, 116 patients with community-acquired pneumonia (CAP) might belong to the outbreak based on epidemiological investigations, but acute laboratory tests other than serology were negative or not performed.

To assess the true extent of the outbreak, they evaluated two serological assays in order to reclassify the 116 patients with indeterminate case status. The two commercial polyvalent serological L. pneumophila assays were used for evaluation of the methods and the outbreak investigation: a serogroup 1–6 immunoglobulin (Ig) G/IgM/IgA immunofluorescence assay (IFA) (Meridian Bioscience Europe; Milan, Italy) and a serogroup 1–7 enzyme-linked immunosorbent assay (ELISA) (Serion ELISA classic, Institut Virion/Serion GmbH; Würzburg, Germany) with separate levels of IgG and IgM antibodies measured in an ELISA robot (DSX Automated System, Dynex Technologies; Inc., Chantilly, VA, USA). Antibodies to the outbreak strain were determined by immunoblotting.

In the evaluation study, the sensitivity and specificity of an equal to or greater than four-fold IFA titre change was 38% and 100%, respectively, with corresponding values of 30% and 99% for seroconversion in ELISA. A single high positive IFA titre yielded sensitivity and specificity of 73% and 97%, respectively, with corresponding values of 68% and 96% for a single high immunoglobulin (Ig) G and/or IgM in ELISA.

The serological testing identified 47 more LD cases, and the outbreak thus comprised 103 cases with a case fatality rate of 10%. About the same proportion (70%) of the urinary antigen positive and negative LD cases had antibodies to the serogroup-specific lipopolysaccharide of the outbreak strain. In addition to the 103 LD cases, Legionella infection could not be verified or excluded in 32 patients based on epidemiology and/or lack of microbiological sampling.

The authors concluded that the acute-phase tests including culture, polymerase chain reaction, and urinary antigen identified less than 55% of the 103 patients in this outbreak. Serological testing thus remains an important supplement for diagnosis of LD and for determination of outbreak cases. The study was published on March 28, 2015, in the journal BMC Infectious Diseases.

Related Links:

Ostfold Hospital Trust
Meridian Bioscience Europe 
Dynex Technologies 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.