Simple Colorimetric Assay Determines Human Mercaptalbumin Concentration

By LabMedica International staff writers
Posted on 30 Jun 2022
Print article
Image: VICTOR Nivo Multimode Microplate Reader (Photo courtesy of PerkinElmer)
Image: VICTOR Nivo Multimode Microplate Reader (Photo courtesy of PerkinElmer)

Human serum albumin (HAS) can take on two forms, mercaptalbumin (HMA) or non-mercaptalbumin (HNA), depending on the redox status of its Cys34. The ratio of HMA and HNA is considered to be a novel biomarker of oxidative stress.

The majority of studies on the redox state of HSA utilize high performance liquid chromatography (HPLC). Several recent studies have also employed mass spectrometry, which yields a higher resolution, thus allowing for finer distinctions between molecular structures. A handful of studies have explored alternative approaches using simple dye-based assays.

Clinical Laboratorians at The University of Tokyo Hospital (Tokyo, Japan) collaborated with colleagues at Nitto Boseki Co. Ltd., (Kawasaki, Japan) measured the concentrations of HMA in serum samples from 36 healthy subjects based on absorption changes of Michler's Hydrol. Michler's Hydrol (4,4′-Bis(dimethylamino)benzhydrol) is a blue dye with a maximum absorption at 612 nm, and its absorption decreases when it reacts with a thiol group.

After processing the samples, the solution was incubated further at room temperature for 20 minutes and absorbance at 612 nm (A612) was measured by a 96-well plate Nivo 3F microplate reader (PerkinElmer, Waltham, MA, USA). To evaluate the performance of the assays, the correlation was determined by a linear regression between the HMA concentrations obtained by Michler's Hydrol assay and corresponding reference concentrations obtained by HPLC and Bromocresol purple (BCP) assays.

The scientists reported that HMA concentrations obtained by Michler's Hydrol assay were highly correlated (r2 = 0.97) with reference values obtained by HPLC (HMA %) and BCP assay (total albumin). The HNA% obtained by Michler's Hydrol and BCP assays combined also gave a good correlation (r2 = 0.96) and a small deviation (average 2.4%) with respect to HPLC as a reference method. The use of the HMA/HNA ratio, which is a function of oxidation of Cys34, is considered a potential biomarker to assess the severity of chronic diseases for which oxidative stress is a significant etiological manifestation.

The authors concluded that the concentrations of HMA in human serum can be measured by Michler's Hydrol assay, which is based on an approximation of HMA concentrations with Michler's Hydrol's colorimetric changes mainly due to thiols. The assay accuracy was significantly improved by pre-incubation of a subset of the samples with an alkylating agent (iodoacetamide) and subtracting their absorption from the absorption of corresponding samples without alkylation. Proportions of HMA and HNA were also obtained by combining Michler's Hydrol assay and the BCP assay (for total albumin concentration). The results correlated well with HPLC, which has been established as a standard method for HMA/HNA measurement. The study was published on June 8, 2022 in the journal Practical Laboratory Medicine.

Related Links:
The University of Tokyo Hospital
Nitto Boseki Co. Ltd
PerkinElmer

 

Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Centrifuge
Centrifuge 5430/ 5430 R
New
Silver Member
Benchtop Image Acquisition Device
Microwell Imager

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.