We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Vitamin D Levels Determined from Dried Capillary Blood

By LabMedica International staff writers
Posted on 01 Nov 2012
An easy technique has been developed to determine the 25-hydroxyvitamin D level, also known as 25-OH vitamin D status, from dried blood samples on filter paper.

The method allows determination of the 25-OH vitamin D levels independently of venous blood taking, since only sampling of capillary blood is required for this original method, which could be used for screening.

Capillary blood was taken from 96 randomly selected healthy blood donors at the University Medical Center, Johannes Gutenberg-University (Mainz, Germany). Capillary blood for 25-OH vitamin D analysis was obtained with the D-Vital ID dry-blood collection system. Dried capillary blood was eluted by moistening the filter of the sampling device with activating solution and vortexing. The 25-OH vitamin D was extracted by adding precipitation solution, incubation at 37 °C for 30 minutes and followed by centrifugation. The level of 25-OH vitamin D was determined in serum and in the clear supernatant of extracted capillary blood using a commercially available immunoassay.

The mean age of the 96 blood donors was 37 years with a range of 19 to 68 years. The interassay variability was 5.18% ± 3.71%. The intra-assay variability was 3.63% ± 2.52%. The concentrations of 25-OH vitamin D in the serum samples covered the whole range from extremely low concentrations to concentrations above the recommended 25-OH vitamin D target blood concentration for healthy individuals. The 25-OH vitamin D concentration data from extracted dried capillary blood filters correlated very well with data obtained after direct measurement of venous blood samples of the same blood donor. The correlation was linear over the whole range of 25-OH vitamin D concentrations seen in this study. The D-Vital ID dry-blood collection system and the vitamin D immunoassay are products of Immundiagnostik (Bensheim, Germany).

The mean absolute differences in 25-OH vitamin D levels measured between whole venous blood and capillary blood dried on filter paper was only 6.6 nmol/L, with only three out of 96 points falling outside of the two standard deviation intervals indicating good agreement of both tests. The authors note that the sampling of capillary blood must be carried out properly. The test pipette must be filled completely so that exactly 50 μL of capillary blood are dried on the filter. If the pipette is not filled completely the vitamin D concentration will be underestimated. The study was published in the August 2012 edition of the journal Clinical Laboratory.

Related Links:

Johannes Gutenberg-University
Immundiagnostik


Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Binocular Laboratory LED Illuminated Microscope
HumaScope Classic LED
New
Immunofluorescence Analyzer
MPQuanti
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.