Blood Test Can Rapidly Detect Infection Risk

By LabMedica International staff writers
Posted on 11 Dec 2013
A device has been created that is able to detect a person's risk of infection from a drop of blood within minutes, as opposed to current methods, which can take up to two hours.

Neutrophil chemotaxis is critical for defense against infections and its alterations could lead to chronic inflammation and tissue injury and the central role that transient alterations of neutrophil chemotaxis could have on patient outcomes calls for its quantification in the laboratory.

Scientists at the Massachusetts General Hospital (Boston, MA, USA) designed a microfluidic device to study neutrophil chemotaxis from a single droplet of whole blood, which has three main components: a chemokine side chambers (200 × 200 μm), a central whole-blood loading chamber, and migration channels containing red blood cell (RBC) filtering regions.

The filter for each migration channel consists of 10 short channels (length about 75 μm) connected horizontally through an approximately 200-μm-long channel to create 90 degree bending sections capable of trapping the RBCs in order to prevent them from dispersing into the rest of the migration channel. A gradient of the chemoattractant is established along the migration channels by diffusion between the chemoattractant chambers and the central loading chamber.

The assay was validated by comparing neutrophil chemotaxis from finger prick, venous blood and purified neutrophil samples. There was a consistent average velocity of 19 ± 6 μm/minute and directionality of 91.1% between the three sources. The team quantified the variability in neutrophil chemotaxis between healthy donors and found no significant changes over time. The novel whole blood device was also used to monitor neutrophil chemotaxis function in a patient with 24% total body surface area burns over a three-week treatment period.

Daniel Irmia, MD, PhD, an assistant professor at the BioMicro Electrical Mechanical Systems Resource Center (BioMEMS; Boston, MA, USA) and a senior author of the study said, “In many cases, it may not be enough to just count the neutrophils. If neutrophils do not migrate well and cannot reach inside the tissues, this situation could have the same consequences as a low neutrophil count.” The authors concluded that being able to measure patients' risk of infections in a matter of minutes from only a droplet of blood is a significant development and one that will improve current treatment. The study was published on October 2, 2013, in the journal Technology.

Related Links:

Massachusetts General Hospital
BioMEMS Resource Center 



Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Troponin I Test
Quidel Triage Troponin I Test
New
Auto Clinical Chemistry Analyzer
cobas c 703
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.