Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

AGILENT

Agilent provides laboratories worldwide with instruments, services, consumables, applications and expertise, enabling... read more Featured Products: More products

Download Mobile App




Molecular Diagnostic Tool Evaluated for Malaria

By LabMedica International staff writers
Posted on 03 Mar 2014
The diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR has been investigated for diagnosing malaria.

Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections and molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections are needed in laboratory settings of resource-limited countries.

Scientists at the University of Georgia (Athens, GA, USA) working with colleagues in East Africa, obtained 303 blood samples from a survey conducted in the Iringa region of Tanzania. Both thick and thin smears were prepared for each sample and DNA was extracted and isolated as well. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory, the Centers of Disease Control and Prevention (CDC; Atlanta, GA, USA).

A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S ribosomal ribonucleic acid (rRNA) PCR. The Stratagene Mx3000P real-time PCR system (Agilent; Santa Clara, CA, USA) was used to test all samples in both the Ifakara Health Institute (Dar es Salaam; Tanzania) and at the CDC.

Twenty-seven samples out of the 303 tested were found to be positive for both P. falciparum and Plasmodium spp. by PET-PCR when performed in both laboratories. Microscopy detected 11 positive samples (3.63%) among the 303 samples tested, and these microscopy positive samples were confirmed to be positive by PET-PCR. In addition, 16 microscopy-negative samples were found to be positive for both P. falciparum and Plasmodium spp. by PET-PCR. The data showed 100% sensitivity and specificity for the PET-PCR assay and 40% sensitivity and 100% specificity for microscopy.

As the goal moves towards malaria elimination, newer tools that are able to detect all malaria cases, including low-density infections not detectable by microscopy, or rapid diagnostic tests (RDTs), and that are applicable to large-scale screening, are required. The authors concluded that PET-PCR as a new molecular diagnostic tool has similar performance characteristics as commonly used PCR methods, but is less expensive, easier to use, and suitable for large scale-surveillance studies in developing country settings. The study was published on January 27, 2014, in the Malaria Journal.

Related Links:

University of Georgia
Agilent
Ifakara Health Institute




Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
Total Hemoglobin Monitoring System
GREENCARE Hb
New
Vaginitis Test
Allplex Vaginitis Screening Assay
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.