We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Potential New Tool for Cervical Cancer Detection

By LabMedica International staff writers
Posted on 29 Dec 2014
Photoacoustic imaging (PAI) has the potential to be a quicker, cheaper, and less-invasive method for detecting and staging cervical cancer (CC), according to a new study.

Researchers at Central South University (Changsha, China) conducted 30 in vitro experiments with tissue samples representing different cancer stages, using PAI, a hybrid optical imaging technique that combines the high contrast of pure optical imaging with the high spatial resolution and the deep imaging depth of ultrasound. The technique involves short laser pulses, some of which are absorbed by the tissues and converted into heat, leading to rapid thermal expansion inside the tissues that produces ultrasonic waves. The generated waves are then detected by an ultrasonic sensor to form photoacoustic images of the tissues.

In each of the experiments, the researchers embedded one section of normal cervical tissue and one section of cervical lesion (from the same person) in a cylindrical phantom for simultaneous PAI. Part of each sample was also sent to histological evaluation for cross-PAI. By processing all of the imaging data, the researchers obtained a depth maximum amplitude projection (DMAP) image, which shows the PAI contrast of the sample. The researchers used hemoglobin as the contrast agent, since PAI is highly sensitive to abnormal angiogenesis, a hallmark of CC tumors.

The obtained DMAP images were analyzed to evaluate the extent of the angiogenesis for different clinical stages of CC. The results showed stronger absorption from the cervical lesions, relative to that of normal tissue. The difference in mean optical absorption (MOA) between normal tissue and CC lesions showed a statistical significance, and the MOA of the CC lesions were closely related to the severity of CC. The study was published in the January 2015 issue of Biomedical Optics Express.

“Due to the higher hemoglobin concentration, abnormal angiogenesis has higher optical absorptions in certain wavelengths than normal tissues,” said lead author assistant professor of biomedical engineering Jiaying Xiao, PhD. “The technique is noninvasive and can detect the lesions in the cervical canal, an area conventional methods fail to observe. The photoacoustic imaging can also evaluate the invasion depth of cervical lesions more effectively.”

In current clinical practice, the diagnosis of CC is mainly through the cervical screening followed by a necessary biopsy, but this method is labor consuming and expensive, and can only detect superficial lesions around the external cervical orifice. In contrast, PAI is sensitive to the abnormal angiogenesis deep in the biological tissue, and may be capable for the intact scanning both around the external orifice and in cervical canal.

Related Links:

Central South University



Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Community-Acquired Pneumonia Test
RIDA UNITY CAP Bac
New
Centrifuge
Hematocrit Centrifuge 7511M4
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.