We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Diagnostic Techniques Evaluated for Cystic Echinococcosis

By LabMedica International staff writers
Posted on 18 Sep 2018
Cystic echinococcosis (CE) is one of the most widespread helminthic zoonoses and is caused by the tapeworm Echinococcus granulosus complex. CE diagnosis and monitoring primarily rely on imaging techniques, complemented by serology.

The serological approach is usually by the detection of IgG antibodies against hydatid fluid (HF), but the use of this heterogeneous antigenic mixture results in a variable percentage of false positive and negative results, and has shown to be useless for follow-up due to the long persistence of anti-HF antibodies in cured patients.

An international team of scientists collaborating with the Instituto de Salud Carlos III (Madrid, Spain) carried out a retrospective cohort study on a total of 721 serum samples. These were collected from 587 of whom 253 patients with CE diagnosed by ultrasonography (US), 42 from patients with alveolar echinococcosis and 92 from healthy donors. The investigators used two recombinant antigens derived from one of the immunodominant hydatid fluid (HF) antigens (antigen B2) were tested in enzyme-linked immunosorbent assay (ELISA) and in immunochromatographic strips (IC) against the serum samples. The ELISA plates were read at 492 nm in an EAR 400 ELISA reader.

The authors reported that the highest overall sensitivity was obtained with HF in ELISA (85.5%), followed by IC containing HF and 2B2t-HF (83.0% and 78.2%, respectively). The lowest sensitivity was obtained with B2t and 2B2t in ELISA (51.8%). The highest specificity was obtained with IC containing 2B2t-HF (100%), and the lowest with HF-ELISA (78.0%). The lowest cross-reactivity with sera from patients with alveolar echinococcosis was detected with the recombinant antigens in ELISA (9.5% to 16.7%) and the highest with the HF-IC (64.3%). The results of B2t and 2B2t-ELISA were influenced by cyst stage, with low sensitivity for inactive (CE4 and CE5) cysts, and by the drug treatment, with higher sensitivity in patients after drug treatment compared with patients not subjected to drug treatment.

The authors concluded that the two recombinant antigens in ELISA provided promising results for monitoring patients in follow-up, although their use is limited to patients with positive serology against them at the beginning of the follow-up. Potential biological reasons behind the low sensitivity of the recombinant antigens and possible strategies to enhance the performance of CE serology were discussed. The study was published on September 6, 2018, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:
Instituto de Salud Carlos III

Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Respiratory QC Panel
Assayed Respiratory Control Panel
New
Vaginitis Test
Allplex Vaginitis Screening Assay
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.