We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Diagnostic Biomarker Expression Compared for Metastatic Tumors

By LabMedica International staff writers
Posted on 25 Sep 2019
Metastatic mucinous tumors pose a unique diagnostic challenge for the surgical pathologist as their morphologic and clinical characteristics are often nonspecific. The colorectum is the most common site of origin.

Historically, the immunophenotypic characteristics of mucinous tumors demonstrate a great degree of overlap across primary sites. Nonspecific staining characteristics of low-molecular weight-cytokeratins (CK7, CK20) have been well documented in mucinous tumors, including those of ovarian, colorectal, and pulmonary origin.

Pathologists at the University of New Mexico School of Medicine (Albuquerque, NM, USA) and their colleagues have presented a head-to-head comparison of special AT-rich sequence-binding protein 2 (SATB2) and caudal type homeobox 2 (CDX2) expression in a diverse array of primary mucinous tumors. SATB2 and CDX2 immunohistochemical stains were performed on whole sections from 44 mucinous colorectal carcinomas and 175 non-colorectal mucinous tumors. A nuclear scoring system measuring intensity (0–3+) and percentage staining (0 = <5%, 1 = 5%–49%, 2 = ≥50%) was implemented, producing an additive histologic score (H-score). The Ventana Discovery platform (Ventana Medical Systems, Tucson, AZ, USA) was used in application of the SATB2 and CDX2 antibodies.

The scientists reported that SATB2 demonstrated acceptable accuracy at low to moderate expression levels (H-scores of 1–4). With these H-score cutoffs, overall accuracy was greater than 90%. In contrast, CDX2's accuracy rivaled that of SATB2 only at an H-score of 5 (89.0%), as its specificity suffered at lower expression levels (<70.0% at H-scores of 1–4). Using a moderate H-score cutoff of 3 or higher, significant differences for both sensitivity and specificity were identified between SATB2 and CDX2, though these stains were near equivalent when each was interpreted as positive at its respective optimal H-score (SATB2 ≥ 3 and CDX2 = 5).

The authors concluded that SATB2 is a more accurate marker of colorectal origin across a variety of expression levels compared with CDX2 when applied to mucinous tumors from a host of primary sites. However, these stains are near equivalent when each is interpreted at its optimal expression level. The study was published in the September 2019 issue of the journal Archives of Pathology & Laboratory Medicine.

Related Links:
University of New Mexico School of Medicine
Ventana Medical Systems


New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Myeloperoxidase Assay
IDK MPO ELISA
New
Auto Clinical Chemistry Analyzer
cobas c 703
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.