We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Abbott Diagnostics

Abbott Diagnostics provides medical diagnostic instruments, tests, automation and informatics solutions, including cl... read more Featured Products: More products

Download Mobile App




Reference Intervals Established for Serum Ferritin in Chinese Adults

By LabMedica International staff writers
Posted on 12 Nov 2019
As the foundation for the interpretation of medical laboratory data, reference intervals (RIs) for analytes are one of the most widely used clinical decision‐making tool. Nevertheless, although measurement of serum ferritin (SF) has largely replaced laboratory assays of serum iron and transferrin or total iron‐binding capacity in clinical practice, there is no gold‐standard method for measuring SF.

At present, SF can be measured using immunoassays, for example, enzyme‐linked immunosorbent assay (ELISA), electrochemiluminescent immunoassay (ECLIA), chemiluminescent immunoassay (CLIA), or immunoturbidimetric assay. Normally, a small amount of ferritin exists in the peripheral circulating blood and is called serum ferritin.

Clinical Laboratory Scientists at the Shaoxing Hospital of China Medical University (Shaoxing, China PR) obtained the SF test results of all health examinees (8,913 males aged 18‐93 years and 5,397 females aged 18‐90 years) between December 2010 and April 2019 from their laboratory information system. Venous blood samples were obtained from each study participant after a 12‐hours fasting period and collected into BD vacutainer tubes (Becton Dickinson, Franklin Lakes, NJ, USA).

Serum was separated from the blood by centrifugation at 3,000 rpm for 5 minutes at room temperature (18‐25°C). All specimens were quantitatively determined within two hours of collection on an Abbott Architect i2000SR analyzer (Abbott Diagnostics, Chicago, IL, USA) according to the manufacturer's specifications and following the laboratory standard operating procedures. The detection kits and calibrators were provided by Abbott Diagnostics.

The scientists reported that SF levels in females were significantly different from those in males and showed a weak positive correlation with age. The RIs based on parametric approach in males were 66.12‐561.58 µg/L, whereas in all females were 3.59‐269.59 µg/L, females aged <50 years 3.26‐148.02 µg/L and those aged ≥50 years 17.28‐303.27 µg/L. The RIs based on non‐parametric approach in males were 65.00‐571.37 µg/L whereas in all females were 4.00‐254.00 µg/L, females aged <50 years 4.00‐152.00 µg/L and those aged ≥50 years 16.00‐304.05 µg/L.

The authors concluded that the present study has provided evidence that the RIs for SF in Chinese adults are markedly different from the manufacturer's recommended Rls. In Chinese adult females, the age‐specific RIs must be also taken into account. As a result, the establishment of the sex‐ and age‐specific RIs by indirect method using the data from health examination records for SF in their own laboratory would give a better chance to aid the physician in differentiating or considering treatment of iron‐deficiency anemia or a risk of iron overload than using manufacturer's recommended RIs or adopting RIs from other laboratories. The study was published on November 1, 2019 in the Journal of Clinical Laboratory Analysis.

Related Links:
Shaoxing Hospital of China Medical University
Becton Dickinson
Abbott Diagnostics



Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Verification Panels for Assay Development & QC
Seroconversion Panels
New
HIV-1 Test
HIV-1 Real Time RT-PCR Kit
New
Community-Acquired Pneumonia Test
RIDA UNITY CAP Bac
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.