We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

HORIBA Medical

HORIBA ABX designs, develops and distributes worldwide, in vitro diagnostic systems for biological analysis in medica... read more Featured Products: More products

Download Mobile App




Two Automated Hematology Analyzers Compared for Performance

By LabMedica International staff writers
Posted on 17 Dec 2020
A complete blood count (CBC) is a highly automated laboratory test. The use of highly advanced measurement methods increases the accuracy and sensitivity of the determination of individual hematological parameters, especially in the case of white blood cells differentiation.

It is important that the results of laboratory tests obtained using automated analyzers, which are currently able to perform more than 1,000 tests per day, are comparable, repeatable and reliable regardless of the analyzer used and the laboratory in which the analysis was performed.

Medical Laboratorians at the Medical University of Warsaw (Warsaw, Poland) collected 241 peripheral blood samples from adult patients. Samples of peripheral blood came from both healthy patients and those suffering from various pathologies. To perform comparative analysis of hematological parameters, complete blood count with leukocyte differentiation (CBC+ 5-DIFF) and a complete blood count (CBC) without leukocyte differentiation were used.

The complete blood count results were obtained using two automated hematology analyzers: the XN-2000 (Sysmex Corporation, Kobe, Japan) and the Yumizen H2500 (Horiba, Kyoto, Japan). The XN-2000 uses the following methods of fluorescent flow to determine all tested hematological parameters: cytometry, impedance and optical cytometry. Impedance method to count red blood cells (RBC) and platelets, and has an optical measurement channel for reticulocytes in which platelet count can also be measured. The Yumizen H2500 is a quantitative, multi-parameter, automatic hematological analyzer. It uses the double hydrodynamic focusing method, which includes measurement of polychromatic light absorbance and the impedance method.

The scientists reported that reliable leukocyte differentiation results were obtained for blood samples in which the number of white blood cells perceived using an automatic hematological analyzer was within the detection limits for both analyzers. Statistically significant differences were found for four hematological parameters: eosinophil count, immature granulocytes, mean corpuscular hemoglobin concentration (MCHC) and platelet distribution width (PDW).

The comparative study showed agreement between measurements of complete blood count parameters such as leukocyte count (WBC), red blood cell count (RBC), hemoglobin concentration (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (mean cell hemoglobin, MCH), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), and plateletcrit (PCT).

The authors concluded that due to the existence of variability between the results obtained from different hematology analyzers, it is recommended that patient samples be analyzed in the same laboratory using the same analyzer, in order to avoid obtaining divergent results that could be misinterpreted. Incorrect interpretation may affect further clinical management and be a source of uncertainty. The study was published in the November, 2020 issue of the journal Practical Laboratory Medicine.

Related Links:
Medical University of Warsaw
Sysmex Corporation
Horiba



Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Respiratory QC Panel
Assayed Respiratory Control Panel
New
Silver Member
Verification Panels for Assay Development & QC
Seroconversion Panels
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.