Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Luminex Corporation

Luminex develops, manufactures, and markets biological testing technologies with applications in clinical diagnostics... read more Featured Products: More products

Download Mobile App




Assay Developed to Measure Anti-Factor VIII Antibodies

By LabMedica International staff writers
Posted on 21 Nov 2022

Hemophilia is a mostly inherited genetic disorder that impairs the body's ability to make blood clots, a process needed to stop bleeding. This results in people bleeding for a longer time after an injury, easy bruising, and an increased risk of bleeding inside joints or the brain.

The development of neutralizing (inhibitors) and non-neutralizing antibodies (NNAs) is a complication to factor replacement therapy in hemophilia. The diagnostic methods available lack standardization, have high inter-laboratory variation, and false-negative as well as false-positive results may affect treatment.

Medical Laboratory Scientists at the University and Regional Laboratories Region Skåne (Skåne, Sweden) analyzed 112 samples obtained from patients with hemophilia A. They developed a diagnostic approach for measuring neutralizing inhibitors and non-neutralizing antibodies (NNAs) to factor VIII (FVIII) based on the xMAP-based fluorescence immunoassay (xFLI, Luminex Corporation, Austin, TX, USA).

The diagnostic approach developed by the scientists involved an xFLI system that they prepared in the laboratory. With this approach, they used commercially available FVIII concentrates coupled to dye-labeled magnetic beads, which could then be used for immunoassays. The FVIII concentrates were a full-length product (Advate, Lexington, MA, USA) and a product lacking in B domain (NovoEight, Plainsboro, NJ, USA). They compared xFLI-based results with those obtained using an enzyme-linked immunosorbent assay (ELISA) and another approach called the chromogenic Bethesda-Nijmegen Assay (CBA).

The investigators reported that the xFLI system using Advate FVIII concentrate showed a statistically significant correlation with the ELISA system in detecting anti-FVIII antibodies. In analyses of 86 samples, the xFLI system using Advate also showed a significant correlation with results from the CBA system for detecting anti-FVIII antibodies. In investigations comparing the xFLI system with NovoEight FVIII concentrate, significant correlations were also seen with the ELISA approach and with the CBA approach.

Analyses using ELISA and CBA methods demonstrated a concordance of 69.8% with each other. Overall concordance between the xFLI system and the ELISA approach was calculated to be 82.1%, and between the xFLI system and for the CBA approach it was 77.9%. Sensitivity also appeared improved with xFLI than with both ELISA and CBA approaches.

The authors concluded that the anti-FVIII antibody xFLI method is adaptable to clinical practice and more sensitive and reproducible than ELISA and CBA. Actual NNA titers were determined to both full-length and B-domain deleted FVIII. The xFLI is thus valuable for confirmation of all anti-FVIII antibodies. The study was published on October 3, 2022 in the journal Haemophilia.


Gold Member
Veterinary Hematology Analyzer
Exigo H400
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Troponin I Test
Quidel Triage Troponin I Test
New
Lyme Disease Test
Lyme IgG/IgM Rapid Test Cassette
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: Researcher Kanta Horie places a sample in a mass spectrometer that measures protein levels in blood plasma and other fluids (Photo courtesy of WashU Medicine)

Highly Accurate Blood Test Diagnoses Alzheimer’s and Measures Dementia Progression

Several blood tests are currently available to assist doctors in diagnosing Alzheimer's disease in individuals experiencing cognitive symptoms. However, these tests do not provide insights into the clinical... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.