Quantitative Gel Zymography Reappraised for Matrix Metalloproteinases

By LabMedica International staff writers
Posted on 29 Oct 2014
Print article
Image: The gel zymography separation of matrix metalloproteinases (MMPs) on a 7.5% polyacrylamide gel (Photo courtesy of the Italian National Research Council).
Image: The gel zymography separation of matrix metalloproteinases (MMPs) on a 7.5% polyacrylamide gel (Photo courtesy of the Italian National Research Council).
A reappraisal of quantitative gel zymography technique for matrix metalloproteinases (MMPs) in human plasma has been used for comparison with commercially available enzyme-linked immunosorbent assay (ELISA).

The determination of MMPs is relevant in numerous pathophysiological conditions, as imbalanced MMP activity is associated with many clinical conditions, including cardiovascular diseases, especially if associated with extracellular matrix remodeling, but the results obtained are closely linked to the method used and are not directly comparable.

Scientists at the Italian National Research Council (CNR; Pisa, Italy) obtained heparinized blood samples from 25 volunteers. The samples were centrifuged and the serum stored in aliquots at −80 °C. Gel zymography was performed based on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and on the use of gelatin 0.5% as substrate for detection of MMP enzymatic activity. Gelatinolytic activities were detected as unstained bands against the background of Coomassie Blue stained gelatin. In order to quantify the concentrations of the analyzed protein in the unknown samples, a dose-response curve was built in each run.

Total MMP-9 was measured in diluted plasma by specific immunometric assay (R&D Systems; Minneapolis, MN, USA), previously standardized. The working range was 0.19 ng/mL to 16 ng/mL, the sensitivity was 0.05 ± 0.01 ng/mL, and the within-assay variability was 414.3 ± 23.5 ng/mL (5.7%), while the between-assay variability was less than 15%. The concentration of total MMP-9 was measured in parallel using the zymography and ELISA for comparison purposes.

The results obtained by gel zymography analysis of human blood samples using different acrylamide/bis acrylamide ratios indicated that 7.5% gels are the more suitable for visualizing MMP-9 forms. In all conditions, four bands with gelatinolytic activity are found: MMP-9 dimers, MMP-9– tissue inhibitor of metalloproteinase1 (TIMP-1) complex, MMP-9, and MMP-2. The time course of the proteolytic activity of MMPs indicated 16 to 24 hours as optimal incubation time and these optimal parameters were used for routine assay. A linear positive correlation was found between the MMP-9 values of zymography and ELISA with the ELISA values significantly lower than those obtained with zymography.

The authors concluded that the main advantage of gel zymography is that it allows visualization of both the latent and active forms of gelatinases. The presence of MMP dimers and MMP/TIMP complexes in the plasma samples, revealed by gel zymography, could thoroughly characterize the role of MMP in associated diseases. Gel zymography allows separation and visualization of MMP-2 bands, so both MMP-2 and MMP-9 can be determined in the same run from a single biological sample. The study was published in the September 2014 issue of the Journal of Clinical Laboratory Analysis.

Related Links:

Italian National Research Council
R&D Systems 


New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Myeloperoxidase Assay
IDK MPO ELISA
New
H.pylori Test
Humasis H.pylori Card

Print article

Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.