We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

POLYMEDCO

Polymedco is a manufacturer and distributor for clinical laboratory supplies, including diagnostic test kits and devi... read more Featured Products: More products

Download Mobile App




Fecal Immunochemical Test Detects Cancer and Polyps

By LabMedica International staff writers
Posted on 30 Aug 2017
Print article
Image: The Polymedco OC auto 80 analyzer (Photo courtesy of Polymedco).
Image: The Polymedco OC auto 80 analyzer (Photo courtesy of Polymedco).
The most commonly used noninvasive test for colorectal cancer (CRC) screening has been the guaiac fecal occult blood test (gFOBT). The fecal immunochemical test (FIT) detects CRC and colorectal polyps with higher levels of sensitivity than the gFOBT, and may be more acceptable to patients.

The fecal immunochemical test (FIT), has shown to be more sensitive for CRC and colorectal polyps and may be more acceptable to patients because FIT can often be done with one sample, instead of three, and does not require dietary restrictions, such as meat avoidance. Screening can reduce incidence and mortality of CRC, but is often underused.

Scientists at the Veterans Administration San Diego Healthcare System (VASDH, San Diego, CA, USA) conducted a retrospective observational study of 7,898 patients, 50–75 years old, who were offered stool-based CRC screening as part of primary care March 2014 through January 2015. The team performed manual reviews of colonoscopy and pathology reports for veterans with positive results from the tests. The primary outcome was test completion within one year of order; secondary outcomes were positive results and detection of advanced neoplasia by diagnostic colonoscopy. The primary analysis used an intention-to-screen approach, which included all patients with test orders; as-screened analyses were also performed.

Before July 2014, when noninvasive CRC screening was offered, a three-sample Hemoccult Sensa gFOBT test was distributed at point of primary care and returned either by mail or in person. From July to August 2014, VASDHS transitioned to using a one-sample FIT (Polymedco OC auto 80, Cortland, NY, USA), also returned either by mail or in person. Colonoscopy and pathology reports were specifically reviewed to ascertain presence of any advanced neoplasia. Advanced neoplasia in this analysis included any CRC or advanced adenoma.

The investigators obtained 4,662 FIT orders and 3,236 gFOBT orders. In the intention to screen analysis, a significantly higher proportion of subjects completed a FIT (42.6%) than a gFOBT (33.4%). Advanced neoplasia was detected in a significantly higher proportion of subjects offered a FIT (0.79%) than a gFOBT (0.28%). The numbers needed to invite to achieve one additional completed test and identify one additional patient with advanced neoplasia were 11 and 196, respectively. The investigators estimate that for every 1,000 tests, FIT would yield 51 colonoscopies, compared with 42 for gFOBT.

Samir Gupta, MD, MSCS, AGAF, the study’s senior and corresponding author and a staff physician, said, “Many physicians are unaware of the difference between FIT and gFOBT, and potential advantages. One of our hopes is that the paper and other associated literature will help laboratory directors and primary care physicians to realize that making a simple switch could have big benefits for patients.” The study was published in the August 2017 issue of the journal Clinical Gastroenterology and Hepatology.

Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
17 Beta-Estradiol Assay
17 Beta-Estradiol Assay
New
Silver Member
Oncology Molecular Diagnostic Test
BCR-ABL Dx ELITe MGB Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.