We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Newly Developed Automated Immunoassay Analyzed

By LabMedica International staff writers
Posted on 29 Nov 2017
Print article
Image: The ARCHITECT i2000SR immunoassay analyzer (Photo courtesy of Abbott).
Image: The ARCHITECT i2000SR immunoassay analyzer (Photo courtesy of Abbott).
Dipeptidyl peptidase-4 (DPP-4) may be a suitable biomarker to identify people with severe asthma who have greater activation of the interleukin-13 (IL-13) pathway and may therefore benefit from IL-13-targeted treatments.

Increased IL-13 messenger RNA (mRNA) expression and protein concentration in bronchial biopsies, sputum and bronchoalveolar lavage fluid from patients with asthma, compared with healthy individuals, supports a role for IL-13 in the pathophysiology of some types of asthma.

A team of scientists collaborating with those at the Abbott Laboratories (Abbott Park, IL, USA) obtained serum samples from healthy volunteers and from subjects with asthma and type 1 diabetes. They used in DPP-4 concentration assessments, samples obtained from a Phase IIb study of tralokinumab in subjects with severe uncontrolled asthma receiving concomitant high-dose fluticasone and salmeterol. Additional samples, collected for a pre-analytical in-house study to confirm specimen-handling procedures, were provided by consenting volunteers with self-reported asthma.

The team assessed assay performance, utilizing analyses of precision, linearity and sensitivity; interference from common endogenous assay interferents, and from asthma and anti-diabetic medications, were also assessed. The new automated IUO DPP-4 immunoassay was performed on Abbott’s ARCHITECT i System. The immunoassay measurement of DPP-4 has a range from 109 ng/mL to 580 ng/mL. The assay is fully automated with a throughput of 200 tests per hour.

The investigators reported that the total precision of DPP-4 concentration measurement, determined using percentage coefficient of variation, was ≤5% over 20 days. Dilution analysis yielded linear results from 30 to 1,305 ng/mL; the limit of quantitation was 19.2 ng/mL. No notable endogenous or drug interferences were observed at the expected therapeutic concentration. Median DPP-4 concentrations in healthy volunteers and subjects with asthma or Type 1 diabetes were assessed, with concentrations remaining similar in subjects with diabetes and asthma across different demographics.

The authors concluded that their analyses indicate that the ARCHITECT DPP-4 immunoassay is a reliable and robust method for measuring serum DPP-4 concentration. The assay is currently being applied to assess the clinical utility of DPP-4 as a predictive biomarker in Phase III studies of tralokinumab in subjects with uncontrolled asthma. The study was published online on October 20, 2017, in the journal Practical Laboratory Medicine.

Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
New
Chemistry Analyzer
MS100

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.