We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Meta-Analysis Finds Home-Based Test Effective for Colorectal Cancer Screening

By LabMedica International staff writers
Posted on 10 Feb 2014
Print article
Image: Patient-friendly fecal immunochemical tests (FITs) – effective tool for colorectal cancer screening (Photo courtesy of Kaiser Permanente).
Image: Patient-friendly fecal immunochemical tests (FITs) – effective tool for colorectal cancer screening (Photo courtesy of Kaiser Permanente).
The largest and most comprehensive evidence review to date indicates that the patient-friendly and simple home-based test is a valuable colorectal cancer-screening tool.

Tests that require patients to collect a single stool sample at home and then send it to a lab for analysis detect about 79% of colorectal cancers (CRCs), according to a new evidence review now published by Lee, et al. in the journal Annals of Internal Medicine, February 4, 2014. The review of 19 studies examining eight different fecal immunochemical tests (FITs) also finds that such tests will correctly identify about 94% of patients who do not have cancers of the rectum or colon. "Now we also know that [FIT] is a great tool for assessing which patients have [this] cancer and which patients don’t,” said Beth Liles, MD, clinical investigator at the Kaiser Permanente Center for Health Research in Portland (OR, USA) of Kaiser Permanente (Oakland, CA, USA).

“The American Cancer Society and other professional organizations have recommended FIT as a screening tool for CRC since 2008, but there are still many people who don’t know about it,” said Jeffrey Lee, MD, MAS, and postdoctoral researcher at the Kaiser Permanente Division of Research and at the University of California, San Francisco. Unlike older stool tests, FIT does not require people to restrict their diets or to stop taking medications. Conducted annually, FIT detects small amounts of blood in the stool; people who test positive are much more likely to have CRC and so would need a follow-up colonoscopy.

The evidence review found that the FITs were fairly sensitive. On average, the tests detected 79% of CRCs with only one round of testing. The tests were also highly specific: on average, 94% of people who did not have cancer tested negative with a single FIT. By comparison, studies indicate that the at-home fecal occult blood test (FOBT) test, which requires 3 stool samples as well as medication and dietary restrictions, detects only about 13% to 50% of CRCs after a single round of testing.

According to the review, no single FIT performed markedly better than another, but the authors caution that there was only one study comparing brands head-to-head. Most of the FITs required collection of only one stool sample. Surprisingly, brands requiring two or three stool samples were no more accurate than those requiring only one.

The 19 studies included 80 to 27,860 patients, with the average age ranging from 45 to 63. Study settings varied. Eligibility criteria were to include all studies evaluating the diagnostic accuracy of FITs for CRC in asymptomatic, average-risk adults. The review was limited to studies in the English language. Two reviewers independently extracted data and critiqued study quality. In 12 of the studies, all patients took the FIT and received a colonoscopy. In seven studies, patients only had a colonoscopy to follow-up on a positive FIT. Approximately 2 years later, researchers followed up with patients who had had a negative FIT to determine whether they had been diagnosed with CRC.

FITs were concluded to be moderately sensitive, highly specific, and with high overall diagnostic accuracy for detecting CRC. Sensitivity for CRC improved with lower assay cutoff values for a positive test result but with a corresponding decrease in specificity. The study was part of Kaiser Permanente’s ongoing efforts to promote prevention and evidence-based care. Another Kaiser Permanente study also found that patients who visited their doctor for any reason were nearly 6 times more likely to be screened for CRC compared to those who did not visit their doctor.

Related Links:

Kaiser Permanente
Kaiser Permanente Division of Research


New
Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Automated Blood Typing System
IH-500 NEXT
New
Urine Strips
11 Parameter Urine Strips
New
Histamine ELISA
Histamine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.