We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Lateral Flow Assay Detects Leprosy Immune Response

By LabMedica International staff writers
Posted on 22 May 2014
Print article
Image: Packard FluoroCount microtiter-plate reader adapted to read lateral flow strips (Photo courtesy of PerkinElmer).
Image: Packard FluoroCount microtiter-plate reader adapted to read lateral flow strips (Photo courtesy of PerkinElmer).
Image: The ESEQuant Lateral Flow Assay Reader (Photo courtesy of Qiagen).
Image: The ESEQuant Lateral Flow Assay Reader (Photo courtesy of Qiagen).
Field-applicable tests detecting asymptomatic Mycobacterium leprae infection or predicting progression to leprosy are urgently required to determine both cellular and humoral immunity.

Leprosy, a curable infectious disease caused by M. leprae that affects the skin and peripheral nerves, is one of the six diseases considered as a major threat in developing countries as continued transmission in endemic areas likely occurs from the large reservoir of individuals who are infected subclinically.

Infectious disease specialists at the Leiden University Medical Center (The Netherlands) with colleagues in Ethiopia recruited for their study human immunodeficiency virus (HIV)-negative, newly diagnosed untreated leprosy patients, and healthy endemic controls from October 2011 until November 2012. Leprosy was diagnosed based on clinical, bacteriological and histological observations and classified by a skin biopsy.

The combined diagnostic value of interferon (IFN)-γ induced protein 10 (IP-10), interleukin-10 (IL-10) and anti-Phenolic Glycolipid-I (PGL-I) antibodies was tested using M. leprae-stimulated blood of leprosy patients and endemic controls (EC). For reduction of the overall test-to-result time, the minimal whole blood assay time required to detect distinctive responses was investigated. To accommodate Lateral Flow Assays (LFAs) for field settings, dry-format LFAs for IP-10 and anti-PGL-I antibodies were developed allowing storage and shipment at ambient temperatures. Additionally, a multiplex LFA-format was applied for simultaneous detection of anti-PGL-I antibodies and IP-10. For improved sensitivity and quantitation, upconverting phosphor (UCP) reporter technology was applied in all LFAs.

After immunochromatography, LF strips are scanned in a Packard FluoroCount microtiter- plate reader (PerkinElmer; Waltham, MA, USA) adapted with an infrared laser. Upon IR excitation at 980 nm, UCP reporter particles emit green light detectable using a 550 nm band pass filter. For strip analysis in Ethiopia, a lightweight portable LF strip reader with UCP capability was used (UCP-Quant, an ESEQuant LFR reader custom adapted with IR diode; (QIAGEN Lake Constance GmbH; Stockach, Germany).

Single and multiplex UCP-LFAs correlated well with enzyme-linked immunosorbent assays (ELISAs) run in parallel. The performance of dry reagent assays and portable, lightweight UCP-LF strip readers indicated excellent field-robustness. Notably, detection of IP-10 levels in stimulated samples allowed a reduction of the whole blood assay time from 24 hours to six hours. Moreover, IP-10/IL-10 ratios in unstimulated plasma differed significantly between patients and endemic controls, indicating the feasibility to identify M. leprae infection in endemic areas.

The authors concluded that dry-format UCP-LFAs are low-tech, robust assays allowing detection of relevant cytokines and antibodies in response to M. leprae in the field. The high levels of IP-10 and the required shorter whole blood assay time, render this cytokine useful to discriminate between leprosy patients and endemic controls. The study was published on May 8, 2014, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:

Leiden University Medical Center
PerkinElmer 
QIAGEN Lake Constance GmbH


New
Gold Member
Syphilis Screening Test
VDRL Antigen MR
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Vitamin B12 Test
CHORUS CLIA VIT B12
New
Alpha-1-Antitrypsin ELISA
IDK alpha-1-Antitrypsin ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.