We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Early Warning Biomarker Found for Chronic Kidney Disease

By LabMedica International staff writers
Posted on 18 Nov 2015
Print article
Image: The suPARnostic kit measures soluble urokinase-type plasminogen activator receptor, a biomarker for kidney disease, by lateral cytometry test in plasma. The reading is performed in a small colorimeter (Photo courtesy of ViroGates).
Image: The suPARnostic kit measures soluble urokinase-type plasminogen activator receptor, a biomarker for kidney disease, by lateral cytometry test in plasma. The reading is performed in a small colorimeter (Photo courtesy of ViroGates).
Image: suPARnostic is be measured by enzyme-linked immunosorbent assay (ELISA), which takes place in less than two hours to obtain robust and reproducible results. There are presentations: Standard suPARnostic ELISA - 41 samples in duplicate; five points on the standard curve; and Flex suPARnostic ELISA - Completely modular -24 × 1, 12 × 5 or 93 samples, quantitative results in less than two hours (Photo courtesy of Rafer SL).
Image: suPARnostic is be measured by enzyme-linked immunosorbent assay (ELISA), which takes place in less than two hours to obtain robust and reproducible results. There are presentations: Standard suPARnostic ELISA - 41 samples in duplicate; five points on the standard curve; and Flex suPARnostic ELISA - Completely modular -24 × 1, 12 × 5 or 93 samples, quantitative results in less than two hours (Photo courtesy of Rafer SL).
A simple blood test for a specific protein can predict a person's chances of developing chronic kidney disease five years before symptoms emerge, thus doing for kidney disease what cholesterol has done for cardiovascular disease.

Relatively high plasma levels of the specific protein soluble urokinase-type plasminogen activator receptor (suPAR) have been associated with focal segmental glomerulosclerosis and poor clinical outcomes in patients with various conditions.

Scientists at Rush University Medical Center (Chicago, IL, USA) and a large team of collaborators, measured plasma suPAR levels in 3,683 persons enrolled in the Emory Cardiovascular Biobank and determined renal function at enrollment. Their mean age was 63 years; 65% were men; and the median suPAR level, 3,040 pg/mL and at subsequent visits in 2,292 persons. The relationship between suPAR levels and the estimated glomerular filtration rate (eGFR) at baseline, the change in the eGFR over time, and the development of chronic kidney disease (eGFR <60 mL per minute per 1.73 m2 of body-surface area) were analyzed.

Serum concentrations of high-sensitivity C-reactive protein (CRP) were determined with the use of a particle-enhanced immunoturbidimetry assay (FirstMark; GenWay Biotech, San Diego, CA, USA) that has a lower limit of detection of 0.03 mg/L. Plasma levels of suPAR were measured with the suPARnostic kit (ViroGates; Birkerød, Denmark), which has a lower limit of detection of 100 pg/mL. The intra-assay variation is 2.75% and the interassay variation is 9.17%.

Of the 2,292 enrollees, 40% of subjects with high suPAR levels, greater than 3,040 ng/mL but no known kidney disease as indicated by, healthy eGFR levels, went on to develop chronic kidney disease over the course of five years. In comparison, only 10% of those with low suPAR levels at baseline developed the disease. Moreover, suPAR was shown to predict eGFR decline in patients with already established earlier stage kidney disease as well. From a cohort of patients with cardiovascular disease, the study divides suPAR levels into four quartiles: normal suPAR: less than 2,373 pg/mL; above normal: 2,373–3,030 pg/mL, high: 3,040–4,020 pg/mL, and very high: above 4,020 pg/mL.

Sanja Sever, PhD, the study's co-first author, said, “What we've shown is that it doesn't matter whether our subjects were black or white. SuPAR was a strong independent predictor of eGFR decline. APOL1 gene polymorphism is a genetic risk factor for renal disease in the black population, but suPAR's power to predict renal disease appeared not be majorly different in black or white patients.” The authors concluded that elevated plasma suPAR levels were associated with incident chronic kidney disease and a more rapid decline in the eGFR in persons with normal kidney function at baseline. The study was published on November 5, 2015, in the New England Journal of Medicine.

Related Links:

Rush University Medical Center 
FirstMark 
ViroGates 


New
Gold Member
Syphilis Screening Test
VDRL Antigen MR
Automated Blood Typing System
IH-500 NEXT
New
Silver Member
Apolipoprotein A-I Assay
Apo A-I Assay
New
Herpes Virus Test
Human Herpes Virus (HHV-6) Real Time PCR Kit

Print article

Channels

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.