Clinical Utility of Anti-Platelet Factor 4 ELISA Test Characterized

By LabMedica International staff writers
Posted on 29 Nov 2015
Print article
Image: LIFECODES PF4 Enhanced and PF4 IgG anti-platelet factor 4 enzyme-linked immunosorbent assays have been designed to detect antibodies that have been implicated in causing Heparin Induced Thrombocytopenia (HIT) (Photo courtesy of Immucor GTI Diagnostics).
Image: LIFECODES PF4 Enhanced and PF4 IgG anti-platelet factor 4 enzyme-linked immunosorbent assays have been designed to detect antibodies that have been implicated in causing Heparin Induced Thrombocytopenia (HIT) (Photo courtesy of Immucor GTI Diagnostics).
Diagnosing heparin-induced thrombocytopenia, a potentially catastrophic immune-mediated disorder, continues to pose significant challenges for clinicians, as both clinical and laboratory tools lack specificity.

There is mounting evidence supporting a positive correlation between definitive heparin-induced thrombocytopenia and optical density (OD) positivity from the widely available anti-platelet factor 4 enzyme-linked immunosorbent assays (PF4 ELISAs); however, the clinical features distinguishing these patients remain poorly understood.

Scientists at the NYU Langone Medical Center (New York, NY, USA) conducted a case-controlled, retrospective chart review of patients from two large, urban academic institutions who underwent a PF4 ELISA at a central laboratory between July 1, 2009, and July 1, 2014. PF4 ELISA assay is a polyimmunoglobulin assay (anti-immunoglobulin G (IgG)/IgAIg/M) utilizing 60 units of heparin in the positive control. Internal positive and negative control values were recorded for each patient’s PF4 ELISA.

The PF4 ELISA testing was performed using the LIFECODES PF4 Enhanced assay kit (Immucor GTI Diagnostics, Inc., Waukesha, WI, USA). In total, 184 negative patients (OD less than 0.7), and 121 positive patients (OD greater than 0.7), including 74 low-positive patients (0.7, OD less than 1.4) and 47 high-positive patients (OD greater than 1.4) were identified. Several clinical variables were significantly different in the negative group compared with the positive group, including hospital day, previous admission within the past three months, and the presence of a new thrombus. However, many of these variables were not different between the negative and low-positive group, and were only distinct between the negative and high-positive group. When the low-positive and high-positive groups were compared, only the 4T score was significantly different.

The authors concluded that patients with high-positive ODs represent a distinct clinical group when compared with low-positive ODs. However, no single characteristic analyzed was able to distinguish those with a low-positive PF4 ELISA OD and those with a high-positive PF4 ELISA OD. Our findings reinforce the clinical utility of the 4T score, which was the only clinical variable that significantly distinguished low-positive and high-positive groups. The study was published on November 19, 2015, in the Journal of Blood Medicine.

Related Links:

NYU Langone Medical Center 
Immucor GTI Diagnostics, Inc. 


Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Chemistry Analyzer
MS100
New
Lab Sample Rotator
H5600 Revolver

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.