Circulating Immune Cells Act As Idiopathic Pulmonary Fibrosis Biomarkers

By LabMedica International staff writers
Posted on 14 Sep 2016
Print article
Image: The BD LSRII flow cytometer (Photo courtesy of Becton Dickinson).
Image: The BD LSRII flow cytometer (Photo courtesy of Becton Dickinson).
Patients with fibrotic lung diseases, such as idiopathic pulmonary fibrosis (IPF), show progressive worsening of lung function with increased shortness of breath and dry cough.

To-date, this process is irreversible, which is why scientists are searching for novel biomarkers or indicators, which enable earlier diagnosis of this disease, with the aim to better interfere with disease progression.

Scientists at the Helmholtz Zentrum München (Munich, Germany) prospectively included 170 patients in the analysis, divided into 69 IPF, 56 non-IPF interstitial lung disease (ILD), 17 with hypersensitivity pneumonitis, 27 with nonspecific interstitial pneumonia, 12 with connective tissue disease- (ILD), and 23 chronic obstructive pulmonary disease (COPD) patients, as well as 22 healthy controls.

For immunophenotyping, the team collected fresh venous blood in EDTA-coated vacutainer tubes. Briefly, whole blood or peripheral blood mononuclear cell (PBMC) buffy coats were used for flow cytometry detection of myeloid-derived suppressor cells (MDSC) and lymphocyte subtypes. Erythrocytes were lysed with a Coulter Q-Prep working station (Beckman Coulter, Brea, CA, USA). Data acquisition was performed in a BD LSRII flow cytometer or a BD fluorescence-activated cell sorter (FACS) ARIA II (Becton Dickinson, Heidelberg, Germany) if cells were sorted. The T-cell suppression assay and MDSC co-cultures were also performed.

Peripheral blood mononuclear cell (PBMC) Messenger ribonucleic acid (mRNA) levels were analyzed by real time polymerase chain reaction (qRT-PCR). The investigators detected increased MDSC in IPF and non-IPF ILD compared with controls (30.99 ± 15.61% versus 18.96 ± 8.17%). Circulating MDSC inversely correlated with maximum vital capacity in IPF, but not in COPD or non-IPF ILD. MDSC suppressed autologous T-cells. The mRNA levels of co-stimulatory T-cell signals were significantly downregulated in IPF PBMC. Importantly, CD33+CD11b+ cells, suggestive of MDSC, were detected in fibrotic niches of IPF lungs.

Oliver Eickelberg, MD, a professor and lead investigator said, “We were able to show that MDSC are primarily found in fibrotic niches of IPF lungs characterized by increased interstitial tissue and scarring, that is, in regions where the disease is very pronounced, and as a next step, we seek to investigate whether the presence of MDSC can serve as a biomarker to detect IPF and to determine how pronounced it is. Controlling accumulation or expansion of MDSC or blocking their suppressive functions may represent a promising treatment options for patients with IPF. ” The study was published on September 1, 2016, in the European Respiratory Journal.

Related Links:
Helmholtz Zentrum München
Beckman Coulter
Becton Dickinson
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Gold Member
Syphilis Screening Test
VDRL Antigen MR
New
Vitamin B12 Test
CHORUS CLIA VIT B12

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.