Novel Procalcitonin Immunoassay Analytically Evaluated

By LabMedica International staff writers
Posted on 25 Jan 2017
Print article
Image: The LUMIPULSE G1200 is a robust mid-sized fully automated immunoassay instrument (Photo courtesy of Fujirebio Diagnostics).
Image: The LUMIPULSE G1200 is a robust mid-sized fully automated immunoassay instrument (Photo courtesy of Fujirebio Diagnostics).
The exact definition of sepsis has changed considerably over time, and remains controversial. This is probably due to the fact that sepsis develops as a continuum of severity, ranging from local infection, through bloodstream propagation to septic shock.

Due to the steadily increasing use of procalcitonin (PCT) measurement for diagnosis and management of bacterial infections, the number of PCT immunoassays available on the diagnostic market has increased in recent years, with automated immunoassays replacing the former manual techniques.

Clinical biochemists at the University of Verona carried out an analytical evaluation of a two-step sandwich immunoassay for PCT in human serum and plasma. This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the ELFA immunoassay Vidas BRAHMS PCT.

The assay evaluated was the Lumipulse G BRAHMS PCT immunoassay adapted to be used on the LUMIPULSE G1200 system. The assay is based on ChemiLuminescent Enzyme Immunoassay (CLEIA) technology. Briefly, the PCT molecules present in the test sample bind to monoclonal anti-PCT mouse antibodies and to capture anti-calcitonin mouse antibodies coated on polystyrene beads, thus generating stable immune complexes and the luminescence is monitored at 477 nm. The assay displays an analytical sensitivity of 0.0048 ng/mL, a functional sensitivity of 0.0079 ng/mL and linearity comprised between 0.02 to 85.1 ng/mL and results are available in 30 minutes.

The LOB, LOD and functional sensitivity were 0.001 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent in the range of concentrations between 0.006 to 75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995. The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively.

The authors concluded that the results of the evaluation of Lumipulse G BRAHMS PCT demonstrate that this technique exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market for routine PCT measurement. However, the significant bias shown by comparing the two immunoassays studied emphasizes that longitudinal patient monitoring should be always performed using the same immunoassay. The study was published on December 1, 2016, in the journal Practical Laboratory Medicine.

New
Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
New
Mumps Virus Test
ReQuest Mumps IgG
New
Ross River Virus Test
Ross River Virus Real Time PCR Kit

Print article

Channels

Molecular Diagnostics

view channel
Image: A coronal MRI section shows a high-intensity focused ultrasound lesion in the left thalamus of the brain (Photo courtesy of UT Southwestern Medical Center)

Newly Identified Stroke Biomarkers Pave Way for Blood Tests to Quickly Diagnose Brain Injuries

Each year, nearly 800,000 individuals in the U.S. experience a stroke, which occurs when blood flow to specific areas of the brain is insufficient, causing brain cells to die due to a lack of oxygen.... Read more

Pathology

view channel
Image: As tumor cells flow through these microfluidic chambers, they are subjected to increasing shear stress and sorted based on their adhesion strength (Photo courtesy of UC San Diego)

Microfluidic Device Assesses Stickiness of Tumor Cells to Predict Cancer Spread

Ductal carcinoma in situ (DCIS), a type of early-stage breast cancer, is often referred to as stage zero breast cancer. In many cases, it remains harmless and does not spread beyond the milk ducts where... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.