Low-Volume Aldosterone Immunoassay Validated for Small Samples

By LabMedica International staff writers
Posted on 26 Sep 2017
Print article
Image: The infinite F50 absorbance reader (Photo courtesy of Tecan).
Image: The infinite F50 absorbance reader (Photo courtesy of Tecan).
Heart failure is a severe cardiovascular disease in adults and children and is characterized by structural or functional abnormalities of the heart. Heart failure leads to an inappropriate blood circulation and subsequently to an undersupply of metabolizing tissues with oxygen and nutrients.

The humoral parameter aldosterone is part of the renin-angiotensin-aldosterone system (RAAS), which plays a major role in the body's salt and water balance. In clinical settings, serum aldosterone is recommended as a screening and diagnosis parameter for primary aldosteronism in high-risk patients.

Scientists at the Heinrich-Heine-University Düsseldorf (Germany) developed and validated a bioanalytical assay for the determination of aldosterone concentrations in small sample volumes. An immunoassay was developed based on a commercially available aldosterone enzyme-linked immunosorbent assay (ELISA) kit. Serum samples were donated by healthy volunteers. The optical density was measured using the absorbance reader infinite F50.

The investigators reported that the assay with a range 31.3 pg/mL to 1,000 pg/mL (86.9 pmol/L to 2,775 pmol/L) was characterized by a between-run accuracy from − 3.8% to − 0.8% and a between-run imprecision ranging from 4.9% to 8.9% (coefficient of variation). For within-run accuracy, the relative error was between − 11.1% and + 9.0%, while within-run imprecision ranged from 1.2% to 11.8% (CV). For parallelism and dilutional linearity, the relative error of back-calculated concentrations varied from − 14.1% to + 8.4% and from − 7.4% to + 10.5%, respectively. No impact of hemolysis on accurate sample determinations was observed.

The authors concluded that their present immunoassay is compliant with current bioanalytical guidelines of the European Medicines Agency (EMA) and allows accurate and precise aldosterone determinations in 40 µL serum. As the assay runs with low-volume samples, it is especially valuable for pediatric investigations, but is not limited to this population. The study was published originally published online on July 27, 2017, in the journal Practical Laboratory Medicine.

Related Links:
Heinrich-Heine-University Düsseldorf


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.