We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Diagnostic Techniques Evaluated for Cystic Echinococcosis

By LabMedica International staff writers
Posted on 18 Sep 2018
Print article
Image: A photomicrograph of histological preparation of a liver with numerous cysts of the cestode Echinococcus granulosus, the cause of cystic echinococcosis or hydatid disease (Photo courtesy of D. Kucharski and K. Kucharska).
Image: A photomicrograph of histological preparation of a liver with numerous cysts of the cestode Echinococcus granulosus, the cause of cystic echinococcosis or hydatid disease (Photo courtesy of D. Kucharski and K. Kucharska).
Cystic echinococcosis (CE) is one of the most widespread helminthic zoonoses and is caused by the tapeworm Echinococcus granulosus complex. CE diagnosis and monitoring primarily rely on imaging techniques, complemented by serology.

The serological approach is usually by the detection of IgG antibodies against hydatid fluid (HF), but the use of this heterogeneous antigenic mixture results in a variable percentage of false positive and negative results, and has shown to be useless for follow-up due to the long persistence of anti-HF antibodies in cured patients.

An international team of scientists collaborating with the Instituto de Salud Carlos III (Madrid, Spain) carried out a retrospective cohort study on a total of 721 serum samples. These were collected from 587 of whom 253 patients with CE diagnosed by ultrasonography (US), 42 from patients with alveolar echinococcosis and 92 from healthy donors. The investigators used two recombinant antigens derived from one of the immunodominant hydatid fluid (HF) antigens (antigen B2) were tested in enzyme-linked immunosorbent assay (ELISA) and in immunochromatographic strips (IC) against the serum samples. The ELISA plates were read at 492 nm in an EAR 400 ELISA reader.

The authors reported that the highest overall sensitivity was obtained with HF in ELISA (85.5%), followed by IC containing HF and 2B2t-HF (83.0% and 78.2%, respectively). The lowest sensitivity was obtained with B2t and 2B2t in ELISA (51.8%). The highest specificity was obtained with IC containing 2B2t-HF (100%), and the lowest with HF-ELISA (78.0%). The lowest cross-reactivity with sera from patients with alveolar echinococcosis was detected with the recombinant antigens in ELISA (9.5% to 16.7%) and the highest with the HF-IC (64.3%). The results of B2t and 2B2t-ELISA were influenced by cyst stage, with low sensitivity for inactive (CE4 and CE5) cysts, and by the drug treatment, with higher sensitivity in patients after drug treatment compared with patients not subjected to drug treatment.

The authors concluded that the two recombinant antigens in ELISA provided promising results for monitoring patients in follow-up, although their use is limited to patients with positive serology against them at the beginning of the follow-up. Potential biological reasons behind the low sensitivity of the recombinant antigens and possible strategies to enhance the performance of CE serology were discussed. The study was published on September 6, 2018, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:
Instituto de Salud Carlos III
New
Gold Member
Pneumocystis Jirovecii Detection Kit
Pneumocystis Jirovecii Real Time RT-PCR Kit
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Auto-Chemistry Analyzer
CS-1200
New
Urine Strips
11 Parameter Urine Strips

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.