Mobile Device Performs Laboratory-Quality HIV Testing

By LabMedica International staff writers
Posted on 21 Feb 2013
Print article
Image:The mChip mobile device (Photo courtesy of Prof. Samuel K. Sia).
Image:The mChip mobile device (Photo courtesy of Prof. Samuel K. Sia).
A low-cost mobile device has been engineered that combines cell phone and satellite communication technologies with fluid miniaturization techniques and performs all essential enzyme-linked immunosorbent assay (ELISA) functions.

The device combined the portability of mobile technology with the detection potential of enzyme-linked antibodies to create a fully automated and portable microfluidic device dubbed the “mChip,” and has been tested in an African setting.

A team of scientists including those at Columbia University (New York, NY, USA) who invented the device assessed its ability to perform serodiagnostic testing for human immunodeficiency virus (HIV) in a field setting and synchronize the results in real time with electronic health records. They tested serum, plasma, and whole blood samples collected in Rwanda and on a commercially available sample panel made of mixed antibody titers.

The handheld apparatus, which is a mobile microfluidic chip for immunoassay on protein markers (mChip) device, captures the essential functions of ELISA as performed by pipetting robots, microplate readers, desktop computers, and communication hardware. The device does not need grid-based power and is sufficiently low in cost and energy consumption to be suitable for resource-limited settings. ELISA is the most sensitive and commonly used laboratory diagnostic for HIV, and historically has taken hours and sometimes days to provide a result. The mChip device, however, produces a result in just 15 minutes.

To explore the performance of the mChip device on coinfected samples, the team evaluated the HIV accuracy of the mChip device on 167 Rwandan patient samples. Also, 100 plasma samples from Rwandan patients were tested for hepatitis B and C (HBV and HCV), as well as 67 serum samples from patients who were also tested for syphilis and herpes simplex virus (HSV-2). Despite the high prevalence of viral hepatitis, 99 positive for HBV and/or HCV in the sample set and the substantial number of sexually transmitted infections, 31 positive for syphilis and/or HSV-2, the diagnostic sensitivity of the mChip device was high at 100%, as was the diagnostic specificity at 99%, with only two false positives.

Samuel K. Sia, PhD., a bioengineer and the senior author of the study, referring to the data repository that doctors can access, said, "Now, with a single push of a button, there is automation not only from the sample to the result, but to the synchronization of data to the cloud. This automation is very important because it minimizes user error and user variability. The real power is that one finger prick can give you multiple rapid test results, making it cheaper and more convenient.” The cost of the device is estimated at USD 100. The study was published on January 17, 2013, in the journal Clinical Chemistry.

Related Links:
Columbia University


Gold Member
Troponin T QC
Troponin T Quality Control
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Liquid Based Cytology Production Machine
LBP-4032
New
Histamine ELISA
Histamine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Molecular Diagnostics

view channel
Image: This medium is used to grow malaria parasites (Photo courtesy of Kyle Dykes/UC San Diego Health Sciences)

New Approach to Help Predict Drug Resistance in Malaria and Infectious Diseases

Malaria, a disease transmitted by mosquitoes that affects millions worldwide, remains a significant public health concern, especially in tropical and subtropical regions. Despite significant efforts to... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.