Novel LC-MS/MS Assay Detects Low Creatinine in Sweat and Saliva

By LabMedica International staff writers
Posted on 01 Jan 2025
Print article
Image: The LC-MS/MS assay can serve as a reference method to validate emerging biosensors for renal function monitoring (Photo courtesy of 123RF)
Image: The LC-MS/MS assay can serve as a reference method to validate emerging biosensors for renal function monitoring (Photo courtesy of 123RF)

Timely and accurate monitoring of renal function is essential for managing patients at risk of acute kidney injury (AKI), which affects about 12% of hospitalized patients and up to 57% of ICU patients. In approximately 20% of these cases, the condition progresses to more severe stages of AKI, leading to longer hospital stays, higher mortality rates, and an increased need for invasive renal replacement therapies. Early intervention, driven by frequent or continuous monitoring of renal function biomarkers like creatinine, could potentially delay this progression. As renal failure can advance quickly, frequent venipuncture for creatinine testing is required. Recent advances in microfluidic devices and biosensors have led to the exploration of alternative biofluids, such as sweat and saliva, for non-invasive, continuous monitoring of creatinine. Researchers have now developed a novel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) assay for detecting low creatinine levels in these biofluids.

Researchers at Eindhoven University of Technology (Eindhoven, The Netherlandsl) investigated the correlation between creatinine concentrations in sweat, saliva, and plasma during hemodialysis, with an eye toward future biosensor applications. They measured creatinine levels in sweat, saliva, and plasma from 40 patients undergoing hemodialysis. Using the novel LC-MS/MS assay, they quantified low creatinine concentrations in these biofluids. Correlation analyses were conducted to compare creatinine levels across the biofluids. The LC-MS/MS assay demonstrated excellent accuracy (93.9% to 97.8%) and low imprecision (3.4% to 8.1%) for measuring very low creatinine concentrations, with a limit of quantitation of 1.26 µmol/L.

The study revealed strong correlations between creatinine concentrations in sweat and saliva compared to plasma (ρ: 0.68 and 0.80, respectively). During hemodialysis, creatinine concentrations declined similarly across all three biofluids. These strong correlations suggest that sweat and saliva could serve as reliable, non-invasive alternatives to traditional blood tests for assessing kidney function. This research improves the understanding of creatinine excretion pathways and lays the groundwork for the development of patient-friendly, continuous kidney function monitoring methods, such as wearable biosensors.

Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
New
Hepatitis B Test
OnSite HBsAg Rapid Test
New
Basophil Activation Test
Flow CAST Kit

Print article

Channels

Molecular Diagnostics

view channel
Image: RT-QuIC Prion, CSF is the only definitive antemortem clinical test of its kind that doesn’t involve a brain biopsy (Photo courtesy of Mayo Clinic)

CSF Test Distinguishes Prion Disease from Other Causes of Rapidly Progressive Dementia

Rapidly progressive dementias are a category of dementia where patients experience a swift decline from the onset of symptoms to losing functional independence, typically within two years.... Read more

Immunology

view channel
Image: New insights into preterm infant immunity could inform care (Photo courtesy of 123RF)

New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood

Preterm infants are particularly vulnerable due to their organs still undergoing development, which can lead to difficulties in breathing, eating, and regulating body temperature. This is especially true... Read more

Pathology

view channel
Image: The Results Manager System (Photo courtesy of QuidelOrtho)

Informatics Solution Elevates Laboratory Efficiency and Patient Care

QuidelOrtho Corporation (San Diego, CA, USA) has introduced the QuidelOrtho Results Manager System, a cutting-edge informatics solution designed to meet the increasing demands of modern laboratories.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.