We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

MINDRAY In-Vitro Diagnostics

As a global leader in in-vitro diagnostics, Mindray provides a wide range of efficient, reliable IVD solutions for la... read more Featured Products: More products

Download Mobile App




Quantitative Agglutination Determined on Automatic Hematology Analyzer

By LabMedica International staff writers
Posted on 16 Sep 2020
Print article
Image: The Mindray BC-2800 Fully Automatic Hematology Analyzer with 19 Parameters for CBC /Blood Cell Test for Hospital Use (Photo courtesy of Mindray).
Image: The Mindray BC-2800 Fully Automatic Hematology Analyzer with 19 Parameters for CBC /Blood Cell Test for Hospital Use (Photo courtesy of Mindray).
The currently available agglutination identification methods are slide methods and test tube methods. Based on the distribution, uniformity and comprehensive changes of non-aggregated cells and agglutinating cells in the liquid, the agglutination degree and strength can be determined by the naked eye.

The results are subject to the subjective influence of the observers, and it has been shown that the amount of agglutination determined in the same sample by different people and the determination of the same sample by the same person at different times were significantly different, thus affecting the accuracy and reliability of the study.

Medical Laboratorians at the Dalian Medical University (Dalian, China) selected and diluted Type A serum to react with the type B cells and the normal saline group was used as the control group. A red blood cell (RBC) count was performed using an automatic hematology analyzer (Mindray, Shenzhen, China), after incubation in a warm bath for 30 minutes. The degree of agglutination on the glass slide was also recorded. A positive serum of antinuclear antibody (ANA) was collected and RBC agglutination between RBC-O and ANA positive serum was determined using the automatic hematology analyzer method.

The scientists reported that the relationship between the results from the automatic hematology analyzer and the agglutination strength using the glass slide method was determined and showed that there was a good linear relationship between the agglutination index (AGI) and serum antibody concentration. There was a significant difference between the serum of ANA positive patients and the normal control group. The stability test results showed a coefficient of variation (CV) < 10% when using the automatic hematology analyzer, indicating that the reproducibility of the test was good.

The investigators found that when normal human serum (control group) was mixed with red blood cells the value was lower than when mixed with normal saline (AGI). Furthermore, the analysis found that the AGI value was normally distributed, so they believe that healthy donors are likely to have a low level of resistance to RBC antibody. This shows that the automatic hematology analyzer can detect weak agglutination antibody in serum, but classical methods cannot observe this phenomenon.

The authors concluded that the automatic hematology analyzer can not only effectively detect the agglutination antibody in serum, but also provides a new tool for clinical application to detect agglutination with high sensitivity, and is quantitative, objective and accurate. The study has been available online since July 3, 2020 in the journal Clinica Chimica Acta.


New
Gold Member
ANA & ENA Screening Assays
ANA and ENA Assays
Automated Blood Typing System
IH-500 NEXT
New
Repeater Pipette
CAPPR10 Repeater Pipette
New
17 Beta-Estradiol Assay
17 Beta-Estradiol Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.