We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Developed Immunoassay Predicts Benefits of Anti-PD-1 Therapy in NSCLC

By LabMedica International staff writers
Posted on 12 May 2021
Print article
Image: The HISCL-5000 is a fully automated immunoassay system designed for fast, highly sensitive and reliable immunoassay testing (Photo courtesy of Sysmex)
Image: The HISCL-5000 is a fully automated immunoassay system designed for fast, highly sensitive and reliable immunoassay testing (Photo courtesy of Sysmex)
Lung cancer is the most common cause of cancer-related deaths worldwide. However, current targeted therapies and immunotherapies have gradually improved patient survival. Anti-programmed cell death-1 (PD-1) antibodies (Abs) are key drugs in non-small-cell lung cancer treatment; however, clinical benefits with anti-PD-1 monotherapy are limited.

Notably, anti-programmed cell death-1 (PD-1) and anti-PD-ligand1 (PD-L1) antibodies (Abs) as immune-checkpoint inhibitors prolong overall survival in non-small-cell lung cancer (NSCLC), which accounts for approximately 80% of lung cancer. However, clinical benefits with anti-PD-1/PD-L1 monotherapy are limited with only 20%–30% overall response rate.

Oncologists at the Kawasaki Medical School, Okayama, Japan and their colleagues obtained sera from advanced NSCLC patients, who received anti-PD-1 monotherapy as standard therapy in a first-line or later setting. Sera were collected within two months before anti-PD-1 monotherapy and were serially done after anti-PD-1 therapy, then frozen and stored at −80 °C until use. ESO-1 and XAGE1 antigen in tumor tissues were immunohistochemically stained in a previous study.

The team developed a fully automated detection system for NY-ESO-1/XAGE1 Abs using an HISCL series (Sysmex, Kobe, Japan), which performs a chemiluminescent sandwich immunoassay. Sera were diluted 400 times with appropriate solution and reacted with magnetic beads coated with recombinant NY-ESO-1 protein or synthetic XAGE1 peptide (GL Biochemistry, Shanghai, China). The investigators also determined serum Abs stability, performed analysis of interfering substances and antigen absorption tests.

The scientists reported that the HISCL system detected specific serum NY-ESO-1/XAGE1 Abs, where levels in ELISA and HISCL were highly correlated. The Ab levels in HISCL were stable at four temperatures, five freeze/thaw cycles, and long-term storage; the levels were not interfered by common blood components. The Abs levels in 15 NSCLC responders to anti-PD-1 monotherapy were significantly higher than those in non-responders and healthy donors. The AUROC was the highest (0.91) in combinatory prediction with NY-ESO-1/XAGE1 Abs.

The authors concluded that they had developed a fully automated immunoassay system, HISCL, measuring serum NY-ESO-1/XAGE1 Abs that can predict clinical benefits with anti-PD-1 monotherapy in NSCLC. Their serum biomarkers measured using HISCL are clinically meaningful, as the serum Abs obtained noninvasively were relatively stable at various conditions and could be measured easily and rapidly. The study was published on April, 15, 2021 in the journal Clinica Chimica Acta.

Related Links:
Kawasaki Medical School
Sysmex
GL Biochemistry


New
Gold Member
C-Reactive Protein Reagent
CRP Ultra Wide Range Reagent Kit
Automated Blood Typing System
IH-500 NEXT
New
Silver Member
Benchtop Image Acquisition Device
Microwell Imager
New
Histamine ELISA
Histamine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more