We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App





D-Dimer Test Can Still Help Rule Out Pulmonary Embolisms in Hospitalized COVID-19 Patients

By LabMedica International staff writers
Posted on 27 Oct 2021

The D-dimer test can still be helpful in ruling out pulmonary embolisms in hospitalized COVID-19 patients, according to a new study.

Researchers at the University of South Florida Health Morsani College of Medicine (USF Health; Tampa, FL, USA) conducted a single-center, diagnostic study to investigate how well D-dimer testing performed at excluding pulmonary embolism in patients hospitalized with COVID-19. They found that the screening blood test originally validated in seriously ill patients without COVID-19 is still clinically useful for ruling out pulmonary embolism in patients hospitalized with the coronavirus.

Pulmonary embolisms occur when blood clots that form in another part of the body (often the leg), travel through the bloodstream, and lodge in the blood vessels of the lung, decreasing blood flow and causing low oxygen levels. Research indicates COVID-19 patients are three to 10 times more likely to develop pulmonary embolisms than other hospitalized patients, even when they are not as seriously ill or immobilized. Scientists are still investigating why, but it appears the COVID-19 virus may create a cellular environment that promotes clotting by making the inside of blood vessels uneven, irritated, and prone to microtears.

Doctors who suspect pulmonary embolisms routinely rely on widely available D-dimer screening to rule out the potentially life-threatening blood clotting disorder – most commonly in surgical patients immobilized for long periods and patients admitted to intensive care units. D-dimer is a simple blood test that measures protein fragments of blood clots floating in the bloodstream. D-dimer levels, normally undetectable or detectable at very low levels, rise sharply when the body is breaking down the clots. A negative D-dimer test (one that rules out pulmonary embolism) can help patients avoid more expensive, invasive diagnostic tests, like a computed tomography pulmonary angiogram, or CTPA.

The USF Health researchers wondered if the increased risk for blood clotting in COVID-19 patients, and uncertainty of diverse D-dimer values found in earlier smaller studies, reduced the existing screening tool’s ability to correctly rule out pulmonary embolism in COVID patients. The conventional thinking was that D-dimer levels would almost always be high in COVID-19 patients, therefore the test as originally validated (in non-COVID patients) would not be accurate at differentiating COVID patients without clots.

The restrospective study looked at the records of 1,541 patients hospitalized with COVID-19 at Tampa General Hospital from Jan. 1, 2020, to Feb. 5, 2021. They compared plasma D-dimer concentrations with CTPA, the criterion for diagnosing pulmonary embolism, in 287 of those patients. All COVID-19 patients with CTPA evidence of pulmonary embolism had D-dimer levels of 0.05 μg/mL or greater, as did the majority (91.2%) of patients without CTPA evidence of pulmonary embolism. (Concentrations of 0.05 μg/mL and higher are considered positive for pulmonary embolism, while anything below that D-dimer level is negative). The researchers also analyzed whether changing the cutoff levels defining positive or negative D-dimer test results specifically for the COVID patient population might improve the test’s performance.

Within the limitations of this single-center study, setting higher D-dimer thresholds was associated with improved specificity – but at “the cost of an increased false-negative rate that could be associated with an unacceptable patient safety risk,” the study authors wrote. A false-negative result means that the test does not detect a pulmonary embolism when the serious blood clotting problem is very likely present. While clinicians must maintain heightened suspicion for pulmonary embolisms when evaluating symptoms in COVID-19 patients, the overall USF Health study results indicate that the currently available D-dimer test adequately screens for the likelihood of pulmonary embolism in hospitalized COVID patients.

“Our study found that clinicians can feel confident interpreting the D-dimer levels the same in COVID patients as they do in every other patient; we don’t need a special (different) value for COVID patients,” said principal investigator Asa Oxner, MD, associate professor and vice chair of USF Health Internal Medicine. “So, in hospitalized COVID patients, we can appropriately rule out a pulmonary embolism if d-dimer levels are low.”

“The mechanisms of developing pulmonary embolisms may differ for COVID patients, but the resulting physiology is the same for all patients. The little fragments of (undissolved) blood clots are still detectable with D-dimer,” said Oxner.

Related Links:
USF Health 

Gold Member
SARS-COV-2 PLUS UK Real Time PCR kit
SARS-COV-2 PLUS UK REALTIME PCR KIT
Gold Member
COVID-19 Rapid Test
AQ+ COVID-19 Ag Rapid Test
New
Automated Biochemistry Analyzer
AutoChem B861
New
Urine Analyzer
URIT-180
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: RT-QuIC Prion, CSF is the only definitive antemortem clinical test of its kind that doesn’t involve a brain biopsy (Photo courtesy of Mayo Clinic)

CSF Test Distinguishes Prion Disease from Other Causes of Rapidly Progressive Dementia

Rapidly progressive dementias are a category of dementia where patients experience a swift decline from the onset of symptoms to losing functional independence, typically within two years.... Read more

Immunology

view channel
Image: New insights into preterm infant immunity could inform care (Photo courtesy of 123RF)

New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood

Preterm infants are particularly vulnerable due to their organs still undergoing development, which can lead to difficulties in breathing, eating, and regulating body temperature. This is especially true... Read more

Pathology

view channel
Image: The Results Manager System (Photo courtesy of QuidelOrtho)

Informatics Solution Elevates Laboratory Efficiency and Patient Care

QuidelOrtho Corporation (San Diego, CA, USA) has introduced the QuidelOrtho Results Manager System, a cutting-edge informatics solution designed to meet the increasing demands of modern laboratories.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.