Evaluation of Rapid Rabies Tests Reveals Problems with Accuracy

By LabMedica International staff writers
Posted on 06 Jul 2016
Print article
Image: The Rapid Rabies Ag Test Kit is a chromatographic immunoassay for the qualitative detection of Rabies virus antigen (Photo courtesy of Creative Diagnostics).
Image: The Rapid Rabies Ag Test Kit is a chromatographic immunoassay for the qualitative detection of Rabies virus antigen (Photo courtesy of Creative Diagnostics).
If humans bitten by a rabid animal are treated quickly, the disease can usually be prevented but such post-exposure prophylaxis is expensive and should be reserved for bites from animals with confirmed infection, but testing dogs for rabies in resource-poor settings is challenging.

The gold standard for rabies diagnosis is the fluorescence antibody test (FAT), which requires that brain tissue is fixed on microscope slides, stained with fluorescently labelled antibodies, and examined under a fluorescence microscope. Alternative diagnostics include various assays to detect virus, antigen or viral ribonucleic acid (RNA), the latter based on polymerase chain reaction (PCR) technology. All of these tests require laboratory equipment, trained staff, and temperature-sensitive reagents.

Scientists at the Friedrich-Loeffler-Institute (Greifswald-Insel Riems, Germany) and their international colleagues compared six commercial lateral flow devices (LFD) for the diagnosis of rabies and their analytical sensitivity. They examined the sensitivity of the tests, their ability to exclude rabies infection accurately, as well as their specificity, which reflects an accurate positive diagnosis, in comparison with fluorescent antibody tests (FAT) and PCR in over 100 samples from experimentally infected animals and animals infected in the wild.

The investigators found that while all six tests showed good specificity, that is none gave false positives, they found that none of them demonstrated good sensitivity across the different sample sets. In fact, more than half of all positive samples, those with positive FAT and PCR results yielded "false negative" LFD results. Some LFD tests did better than others, and in some cases specific batches of the same test did better than others, but overall the results were disappointing.

The Antigen Rapid Rabies Ag-Test (Bionote Inc, Hwaseong-si, South Korea) displayed a positive rate for seven samples; the Rabies Virus Ag Rapid Test (Green Springs, Shenzhen, China) for 10 samples; the Rapid Rabies Ag Test (Creative Diagnostics, Shirley, NY, USA) for 14 samples. The scientists did report that viral RNA can be stored and eventually extracted from the LFDs using standard procedures available at molecular diagnostic laboratories. In fact, they were able to detect viral RNA after six weeks of storage at room temperature.

The authors concluded that with their current limitations commercially available rabies LFDs cannot be recommended for routine diagnosis and surveillance. If animals were involved in a biting incident to a human being, they note that false negative results may induce the patient and the doctor to refrain from appropriate post-exposure prophylaxis (PEP) given its high cost, even if the leaflet accompanying the test states that results are to be confirmed by a reference method. The study was published on June 23, 2016, in the journal PLOS Neglected Tropical Diseases.

Related Links:
Friedrich-Loeffler-Institute
Bionote
Green Springs
Creative Diagnostics
Gold Member
Troponin T QC
Troponin T Quality Control
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Malaria Rapid Test
OnSite Malaria Pf/Pan Ag Rapid Test
New
Silver Member
Oncology Molecular Diagnostic Test
BCR-ABL Dx ELITe MGB Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.