Robust Method Determines Serum Chromium and Cobalt

By LabMedica International staff writers
Posted on 28 Jan 2015
Print article
Image: The octopole reaction inductively coupled plasma-mass spectrometer system 7500CE ORS-ICP-MS (Photo courtesy of Agilent Technologies).
Image: The octopole reaction inductively coupled plasma-mass spectrometer system 7500CE ORS-ICP-MS (Photo courtesy of Agilent Technologies).
Chromium (Cr) and cobalt (Co) metal ions released from orthopedic prostheses, such as metal-on-metal (MoM) bearings, may be related to wear of the bearing surface and these ions may serve as indicators of the in vivo performance of MoM bearing surfaces.

A simple and sensitive assay has been developed which is suitable for the simultaneous measurement of serum Cr and Co using inductively coupled plasma-mass spectrometry (ICP-MS) which can be used in clinical routine laboratory practice.

Scientists at the Sungkyunkwan University School of Medicine (Seoul, Republic of Korea; www.skkusm.ac.kr) evaluated the clinical usefulness of the assay, in 51 healthy subjects and 74 patients with MoM prosthesis. They collected 185 serum samples from 74 hip resurfacing arthroplasty (HRA) patients including 10 preoperative samples. The assay was validated by evaluating its accuracy, intra- and inter-assay precision, low limit of quantification (LOQ), limit of detection (LOD), and linearity range.

Analyses were performed by inductively coupled plasma-mass spectrometry on a 7500CE ORS-ICP-MS (Agilent Technologies; Santa Clara, CA, USA; www.agilent.com). For reference interval verification of serum Cr and Co levels, 51 healthy subjects were selected among people who had no history of occupational exposure or iatrogenic exposure to metallic implants, such as prostheses, surgical screws, or intrauterine devices.

The serum Cr and Co concentrations were 0.60 ± 0.12 μg/L and 0.29 ± 0.15 μg/L in 51 healthy subjects. In 74 patients (185 serum samples) after HRA with a median duration implanted of 48 months (range, 1 to 138 months), the median concentrations of Cr and Co were 2.75 μg/L (range, 0.61 to 116.8 μg/L) and 1.49 μg/L (range, 0.12 to 127.8 μg/L), respectively. Three patients out of 74 patients showed greater than 20 μg/L of serum Cr and Co levels during postoperative monitoring. Cr and Co levels in seven patient groups receiving HRA were significantly higher without regard to duration of implanted MoM than the levels in the healthy control group.

The author concluded that the simple and robust assay developed for the simultaneous measurement of serum Cr and Co using ICP-MS is easily available in routine clinical laboratory practice. This assay showed good analytical performance including precision, accuracy, linearity and LOQ. It was also assessed using large scale of 236 clinical samples from healthy subjects and patients receiving HRA. This simple assay is good enough to evaluate the nutritional status of Cr and Co in healthy people as well as monitor the performance of orthopedic prosthesis after HRA in routine clinical laboratory practice. The study was published January 15, 2015, in the journal Clinica Chimica Acta.

Related Links:

Sungkyunkwan University School of Medicine
Agilent Technologies 


New
Gold Member
Veterinary Hematology Analyzer
Exigo H400
Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
New
Blood Gas Panel plus Electrolytes
i-STAT EG6+ Cartridge
New
Automated Biochemistry Analyzer
AutoChem B861

Print article

Channels

Molecular Diagnostics

view channel
Image: A coronal MRI section shows a high-intensity focused ultrasound lesion in the left thalamus of the brain (Photo courtesy of UT Southwestern Medical Center)

Newly Identified Stroke Biomarkers Pave Way for Blood Tests to Quickly Diagnose Brain Injuries

Each year, nearly 800,000 individuals in the U.S. experience a stroke, which occurs when blood flow to specific areas of the brain is insufficient, causing brain cells to die due to a lack of oxygen.... Read more

Immunology

view channel
Image: The discovery of biomarkers could improve endometrial cancer treatment (Photo courtesy of Mount Sinai)

Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer

Endometrial cancer, which develops in the lining of the uterus, is the most prevalent gynecologic cancer in the United States, affecting over 66,000 women annually. Projections indicate that in 2025, around... Read more

Pathology

view channel
Image: As tumor cells flow through these microfluidic chambers, they are subjected to increasing shear stress and sorted based on their adhesion strength (Photo courtesy of UC San Diego)

Microfluidic Device Assesses Stickiness of Tumor Cells to Predict Cancer Spread

Ductal carcinoma in situ (DCIS), a type of early-stage breast cancer, is often referred to as stage zero breast cancer. In many cases, it remains harmless and does not spread beyond the milk ducts where... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.