We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Robust Method Determines Serum Chromium and Cobalt

By LabMedica International staff writers
Posted on 28 Jan 2015
Print article
Image: The octopole reaction inductively coupled plasma-mass spectrometer system 7500CE ORS-ICP-MS (Photo courtesy of Agilent Technologies).
Image: The octopole reaction inductively coupled plasma-mass spectrometer system 7500CE ORS-ICP-MS (Photo courtesy of Agilent Technologies).
Chromium (Cr) and cobalt (Co) metal ions released from orthopedic prostheses, such as metal-on-metal (MoM) bearings, may be related to wear of the bearing surface and these ions may serve as indicators of the in vivo performance of MoM bearing surfaces.

A simple and sensitive assay has been developed which is suitable for the simultaneous measurement of serum Cr and Co using inductively coupled plasma-mass spectrometry (ICP-MS) which can be used in clinical routine laboratory practice.

Scientists at the Sungkyunkwan University School of Medicine (Seoul, Republic of Korea; www.skkusm.ac.kr) evaluated the clinical usefulness of the assay, in 51 healthy subjects and 74 patients with MoM prosthesis. They collected 185 serum samples from 74 hip resurfacing arthroplasty (HRA) patients including 10 preoperative samples. The assay was validated by evaluating its accuracy, intra- and inter-assay precision, low limit of quantification (LOQ), limit of detection (LOD), and linearity range.

Analyses were performed by inductively coupled plasma-mass spectrometry on a 7500CE ORS-ICP-MS (Agilent Technologies; Santa Clara, CA, USA; www.agilent.com). For reference interval verification of serum Cr and Co levels, 51 healthy subjects were selected among people who had no history of occupational exposure or iatrogenic exposure to metallic implants, such as prostheses, surgical screws, or intrauterine devices.

The serum Cr and Co concentrations were 0.60 ± 0.12 μg/L and 0.29 ± 0.15 μg/L in 51 healthy subjects. In 74 patients (185 serum samples) after HRA with a median duration implanted of 48 months (range, 1 to 138 months), the median concentrations of Cr and Co were 2.75 μg/L (range, 0.61 to 116.8 μg/L) and 1.49 μg/L (range, 0.12 to 127.8 μg/L), respectively. Three patients out of 74 patients showed greater than 20 μg/L of serum Cr and Co levels during postoperative monitoring. Cr and Co levels in seven patient groups receiving HRA were significantly higher without regard to duration of implanted MoM than the levels in the healthy control group.

The author concluded that the simple and robust assay developed for the simultaneous measurement of serum Cr and Co using ICP-MS is easily available in routine clinical laboratory practice. This assay showed good analytical performance including precision, accuracy, linearity and LOQ. It was also assessed using large scale of 236 clinical samples from healthy subjects and patients receiving HRA. This simple assay is good enough to evaluate the nutritional status of Cr and Co in healthy people as well as monitor the performance of orthopedic prosthesis after HRA in routine clinical laboratory practice. The study was published January 15, 2015, in the journal Clinica Chimica Acta.

Related Links:

Sungkyunkwan University School of Medicine
Agilent Technologies 


Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Silver Member
Apolipoprotein A-I Assay
Apo A-I Assay
New
PSA Test
Human Semen Rapid Test

Print article

Channels

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.