Platelet Counts Compared for Thalassemia Patients

By LabMedica International staff writers
Posted on 13 Jul 2017
Platelet count is the component of complete blood count that is used to diagnose quantitative defect in platelets. More...
Accuracy of platelet count is essential for determining bleeding risk in patients and impedance platelet count is widely used in many clinical laboratories for routine patient testing.

A blood cell or particle fitting the platelet size profile of the platelet distribution curve is counted as a platelet. Although the quality of the impedance method has been continuously improved, inaccurate counting still occurs in many conditions. Abnormal red blood cells (RBCs) with low volume, including microcytes, schistocytes, and spherocytes, have been reported to be the cause of spuriously high platelet counts.

Clinical scientists at Mahidol University (Bangkok, Thailand) included in a study 249 patients with thalassemia who visited the outpatient hematology clinic at Siriraj Hospital, Bangkok, Thailand, during the March 2015 to August 2015. Peripheral blood specimens of study participants were collected in dipotassium ethylenediaminetetraacetic acid tubes and analyzed for platelet count by various methods within four hours after phlebotomy.

The fully automated Sysmex XN-3000 analyzer was used to measure platelet counts for the evaluated measurement methods in the study. To investigate the performance of automated platelet counts, including impedance (PLT-I) and optical fluorescent (PLT-O and PLT-F) methods, were compared with the international reference method (IRM) for platelet counting in patients with thalassemia. Red blood cell measurements were also analyzed on the Sysmex XN-300.

The team included specimens with platelet counts ranging from 31 × 103/μL to 932 × 103/μL and most of the patients were diagnosed with thalassemia major. Correlation between PLT-I and IRM was lower than that of the other methods in overall patients. PLT-O and PLT-F were correlated to IRM when classifying patients according to clinically significant platelet ranges. All automated methods had acceptable sensitivities; however, specificity of PLT-I was low for diagnosis of thrombocytopenia. High RDW-CV (red blood cell distribution width–coefficient of variation) was an independent factor of inaccurate PLT-I measurement.

The authors concluded that among the evaluated methods, PLT-I was the method least correlated to IRM, with PLT-O and PLT-F comparable to IRM in patients with thalassemia. Optical platelet counts and careful blood smear examination are recommended alternative platelet counting methods, depending on the clinical setting. The study was published in the June 2017 issue of the journal Archives of Pathology & Laboratory Medicine.

Related Links:
Mahidol University


Gold Member
Flocked Fiber Swabs
Puritan® Patented HydraFlock®
Online QC Software
Acusera 24•7
Creatinine/eGFR Meter
StatSensor® Creatinine/eGFR Meter
Hematology Consumables
Bioblood Devices
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image:Schematic illustration of plasmonic microarray–based KRAS mutation detection from colorectal cancer patients. (Lee, J.Y., Mun, C.W., Kim, E.R. et al. npj Precision Oncology, 2026. https://doi.org/10.1038/s41698-026-01452-8)

Blood and Urine Liquid Biopsy Detects Early Colorectal Cancer Mutations

Early-stage colorectal cancer is difficult to assess noninvasively because tumor-derived mutations occur at extremely low levels in blood and urine, straining the sensitivity, cost, and turnaround time... Read more

Immunology

view channel
Image:Proteomic tear-fluid analysis revealed abnormal patterns in proteins that regulate nerves and T cells in individuals with eye problems (Image Credit: Adobe Stock)

Diagnostic Models Detect Hidden Eye Abnormalities After Mild COVID-19

Persistent ocular symptoms after COVID-19 can severely affect reading, work, and daily tasks, yet standard eye exams often reveal no clear abnormalities. Patients experiencing photophobia, eye pain, and... Read more

Industry

view channel
Photo courtesy of Natera

Natera’s Signatera Earns IVDR Certification for Solid Tumor MRD Testing

Natera’s Signatera has received certification as a Class C device under the European Union’s In Vitro Diagnostic Regulation (IVDR), becoming the first personalized MRD test for solid tumors to achieve... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.