We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Immunochromatography Tests Evaluated for Detection of Novel Norovirus

By LabMedica International staff writers
Posted on 02 Aug 2015
A novel GII.17 Norovirus has emerged as a major cause of epidemic and endemic acute gastroenteritis in several countries in Asia.

From September 2014 to March 2015, 70% of all outbreaks in Guangdong and Jiangsu provinces in China were caused by a novel GII.17 virus and a similar increase in the number of infections with this novel GII.17 virus has been reported in Japan and Thailand since December 2014.

Microbiologists at Chiang Mai University (Thailand) working with colleagues from Japan, analyzed randomly selected stool samples for which there was a large quantity available—a panel of six GII.17-positive stool samples from five patients in Japan and one in Thailand in which the virus copy numbers had been quantified by real-time reverse-transcriptase polymerase chain reaction (RT-PC R) for reference values. Two of the six GII.17 stool samples tested positive by four immunochromatography (IC) kits.

To evaluate if these IC tests are able to detect these novel GII.17 noroviruses, they tested four commercial kits available in Japan: GE test Noro Nissui (Nissui Pharmaceutical Co., Ltd.; Tokyo, Japan); ImmunoCatch-Noro (Eiken Chemical Co., Ltd.; Tokyo, Japan); Quick Navi-Noro 2 (Denka Seiken Co., Ltd.; Tokyo, Japan); Quick Chaser-Noro (Mizuho Medy Co., Ltd.; Tosu City, Japan).

The six specimens tested by real-time RT-PCR demonstrated that the two samples that were positive by IC test contained high virus titers of 1.90 × 109 and 8.06 × 109 virus copies/mL. In contrast, the other four specimens that were negative in the IC test had virus titers ranging from 4.91 × 103 to 2.50 ×108 virus copies/mL. The results demonstrated that at 1:10 dilution of a virus titer equal to 1.90 × 108 copies/mL, two of three tests still showed the positive results, with a weak positive band, while at 1:100 dilution equal to virus titer 1.90 × 107 copies/mL, all three IC tests were negative. These data demonstrated that the sensitivity of the IC kits for the detection of this novel GII.17 virus was about 108 copies/mL.

The authors concluded that the tested commercial IC kits for the detection Norovirus available on the market in Japan were able to detect the novel GII.17 Norovirus, but with relatively low sensitivity. Only samples that contained more than 109 copies/mL were positive in all four IC tests. They suggest a redesign of the currently available Norovirus IC tests may be required to detect the novel GII.17 noroviruses with the same sensitivity as for the more commonly circulating norovirus genotypes. Laboratories and physicians should be aware of these findings, in particular where the novel GII.17 norovirus has been shown to be circulating.

Related Links:

Chiang Mai University
Nissui Pharmaceutical 
Eiken Chemical 



Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
Total Hemoglobin Monitoring System
GREENCARE Hb
New
Piezoelectric Micropump
Disc Pump
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.