Centrifugal Speed Affects Light Transmission Aggregometry

By LabMedica International staff writers
Posted on 02 Jan 2012
Print article
Light transmission aggregometry (LTA) is considered the gold standard for investigating platelet activity ex vivo, but LTA protocols are not standardized.

Centrifugation speed is an essential component of platelet preparation in LTA and has yet to be standardized, which may affect platelet aggregation leading to a potential source of variance in results.

In a study, conducted at the New York University School of Medicine (NY, USA) the effect of relative centrifugal force (RCF) intensity on LTA results was investigated. Ten healthy controls had venous blood drawn and centrifuged at 150, 200, 300, and 500 × g for 10 minutes. Cell counts in whole blood and platelet-rich plasma (PRP) were measured using a hematology analyzer. LTA was performed using 1.0 µM adenosine diphosphate (ADP) and 0.4 µM epinephrine as an agonist. The percentage of aggregation was compared at 60, 120, 180, and 300 seconds and at maximum aggregation.

Centrifugation speed was associated with a statistically significant decrease in platelet counts and decrease in mean platelet volume in PRP. Consistently, platelet aggregation in response to 0.4 µM of epinephrine decreased significantly with increasing centrifuge RCF at 60, 120, 180, 300 seconds and at maximum aggregation. Whole blood and PRP cell blood count were performed using a Sysmex XE-2100 analyzer (Mundelein, IL, USA). LTA was performed using the AggRAM light transmission aggregometer, reagents, cuvettes, and stir bars (Helena Laboratories, Beaumont, TX, USA).

The authors concluded that using different centrifuge RCF results in changes in PRP properties and LTA. This difference in methodology gives pause to comparing LTA from studies with different protocols and may help explain some of the inconsistencies observed in the field. Consequently, consideration should be given to standardize centrifugation parameters in performing LTA. The study is planned to appear in the February 2012 print edition of the International Journal of Laboratory Hematology.

Related Links:
New York University School of Medicine
Sysmex
Helena Laboratories


New
Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Automated Blood Typing System
IH-500 NEXT
New
Thyroxine ELISA
T4 ELISA
New
Anti-Secukinumab ELISA
LISA-TRACKER anti-Secukinumab

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.