Immunoassays Evaluated for Thyroid-Stimulating Receptor Antibody in Graves’ Disease

By LabMedica International staff writers
Posted on 23 Nov 2021
Print article
Image: The IMMULITE 2000 XPi Immunoassay System provides multiple tests on a single, easy-to-use analyzer, including the thyroid-stimulating immunoglobulin assay (Photo courtesy of Siemens Healthcare)
Image: The IMMULITE 2000 XPi Immunoassay System provides multiple tests on a single, easy-to-use analyzer, including the thyroid-stimulating immunoglobulin assay (Photo courtesy of Siemens Healthcare)
Graves' disease (GD), also known as toxic diffuse goiter, is an autoimmune disease that affects the thyroid. It frequently results in and is the most common cause of hyperthyroidism and it also often results in an enlarged thyroid.

Thyroid-stimulating hormone (TSH) receptor (TSHR) autoantibodies (TRAbs) are pathognomonic of GD and are detected in the serum of approximately 98% of patients with untreated GD. The specific and sensitive detection of thyroid-stimulating immunoglobulin (TSI) from other types of TRAbs is becoming increasingly important for the diagnostic accuracy of the Graves’ hyperthyroidism and of the extrathyroidal manifestations of GD.

Medical Laboratorians at the Shanghai Medical College (Shanghai, China) and their colleagues recruited 559 patients in the period between October 2020 and February 2021. There were 166 GD patients, 81 patients of whom were untreated GD, 393 patients with other thyroid diseases including 79 patients with Hashimoto's thyroiditis, 103 patients with thyroid nodules, 96 patients with hypothyroidism, 59 patients with nontoxic goiter, and 56 patients with thyroid cyst. In addition, 20 euthyroid healthy subjects were recruited as normal controls.

The team evaluated the analytical and clinical performance of two immunoassays for diagnosis of Graves’ disease (GD): the Immulite thyroid-stimulating immunoglobulin (TSI, Siemens Healthcare, Erlangen, Germany), and the Elecsys Anti-TSH receptor (TSHR), assay (Roche Diagnostics, Mannheim, Germany). The Immulite TSI assay is a chemiluminescence immunoassay with the clinical decision point of 0.55 IU/L. The Roche Elecsys Anti-TSHR assay is a competitive assay using electrochemiluminescence detection.

The investigators reported that the repeatability and intermediate imprecision coefficient of variation (CV%) of the TSI assay were 3.8% and 4.1% at 0.95 IU/L, and 3.5% and 3.6% at 19.5 IU/L, respectively. The assays were linear over a range 0.27–38.5 IU/L. There was a high correlation between the quantitative results of the two methods. The cut-off value obtained by ROC analysis for TSI assay was 0.7 IU/L with sensitivity of 93.7% and specificity of 85.1%. An overall qualitative agreement of 91.5% between two methods was observed. Among 44 patients with discordant qualitative results, the TSI assay provided more satisfactory results consistent with clinical diagnoses.

The authors concluded that the Immulite TSI assay specifically measured the pathogenic antibody of GD and exhibited excellent analytical performance. The Immulite TSI assay may be of great value for the clinical diagnosis of GD. The study was published on November 11, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Shanghai Medical College
Siemens Healthcare
Roche Diagnostics


New
Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Automated Blood Typing System
IH-500 NEXT
New
Thyroxine ELISA
T4 ELISA
New
Silver Member
Oncology Molecular Diagnostic Test
BCR-ABL Dx ELITe MGB Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.