Cardiac Valve Pathogens Detected by Multiplex Assay

By LabMedica International staff writers
Posted on 14 Jan 2014
Print article
Image: Scanning electron micrograph of coagulase-negative Staphylococcus aureus bacteria (Photo courtesy of Janice Haney Carr).
Image: Scanning electron micrograph of coagulase-negative Staphylococcus aureus bacteria (Photo courtesy of Janice Haney Carr).
Infective endocarditis (IE) is a life-threatening condition burdened by high mortality, and gram-positive cocci account for the majority of the cases.

Blood culture represents a cornerstone for the microbiological diagnosis of IE, but it can be negative in a substantial number of patients. Similarly, culture of excised cardiac valves can be burdened by a considerable number of false negative results, mostly in patients under antibiotic therapy, or by false positive results, due to contamination.

Microbiologists at the University of Perugia (Italy) carried out a proof of concept study using a commercially available multiplex real-time polymerase chain reaction (PCR) for the detection of pathogens in cardiac valves from patients with infective endocarditis. Between June 2011 and January 2013, 20 cardiac valves, 11 mitral and 9 aortic excised from an equal number of patients with definite IE diagnosis of known etiology were tested by conventional culture and the real-time PCR test. Five aortic valves excised from non-IE patients, affected by noninfective cardiac complications, were included in the study as controls. Mean age of the patients was 64.2 years and all patients were on antimicrobial therapy during sampling.

All excised valves were examined with Gram stain and inoculated into culture media. The commercially available SeptiFast real-time-PCR system (Roche Molecular Systems; Mannheim, Germany) was evaluated as a diagnostic tool for IE and was performed in Roche Diagnostics’ LightCycler instrument. An organism detected by SeptiFast (SF) test was considered true pathogen if it coincided with the infectious agent previously isolated from blood culture, collected from the same IE patient.

The SeptiFast test gave a positive result in 19 out of 20 valves from patients with IE, and a negative result in all the five valves from non-IE patients. In all cases, the organism detected by the test was concordant with the known etiologic agent and Gram staining. Culture was positive in 3 out of 20 valves from IE patients, for microorganisms matching those previously isolated from blood culture and was negative in all valves from non-IE patients, and therefore culture sensitivity was only 15.8%, and specificity was 100%. Gram staining was positive in 16 valves from IE patients, and negative in all non-IE patients.

The authors concluded that the SeptiFast (SF) assay can be used on culture-negative heart valve tissues, excised from patients with IE, showing sensitivity and negative predicative value (NPV) higher than culture, with the same high specificity and positive predictive value (PPV). In cases of SF positive for coagulase-negative staphylococci (CoNS) or streptococci, a DNA sequencing of the amplicons would be required to identify the pathogen at the species level. In case of negative SF result, it would be advisable to test cardiac valves by PCR procedures specific for uncommon infectious agents of IE. The study was published on December 21, 2013, in the journal Diagnostic Microbiology and Infectious Disease.

Related Links:

University of Perugia
Roche Molecular Systems 


Gold Member
Hematology Analyzer
Swelab Lumi
Automated Blood Typing System
IH-500 NEXT
New
Chemistry Analyzer
MS100
New
Rocking Shaker
HumaRock

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.