Performance of Blood Culture Molecular Panels Evaluated

By LabMedica International staff writers
Posted on 06 Sep 2018
Print article
Image: The Verigene Gram-positive blood culture test detects 12 Gram-positive targets and three resistance markers (Photo courtesy of Luminex).
Image: The Verigene Gram-positive blood culture test detects 12 Gram-positive targets and three resistance markers (Photo courtesy of Luminex).
High accuracy of direct identification of pathogens from positive blood culture molecular panels is imperative, particularly for the detection of resistance determinants as it allows for antimicrobial optimization prior to conventional susceptibility testing.

In general, when patients are suspected of having bacteremia or sepsis, clinicians immediately prescribe a broad-spectrum antibiotic aimed at killing most bacteria known to cause the infection. They start de-escalating use of the drugs when they deem it appropriate.

Scientists at the Children’s Hospital Los Angeles (Los Angeles, CA, USA) and their colleagues have provided extensive data of a five-year study since implementation of the Verigene Gram-positive blood culture panel in 2013.

Within five years, 1,636 blood culture bottles positive for a Gram-positive organism were tested on the BC-GP panel. The BC-GP panel identified 1,520 Gram-positive organisms in 1,636 (92.9%) blood cultures tested. For positive blood cultures, they observed 96.4% (806/834) concordance to the species level. Compared with conventional antimicrobial susceptibility testing, the positive percent agreement (PPA) of methicillin-resistant Staphylococcus aureus, SA (MRSA) (50) and methicillin-resistant Staphylococcus epidermidis, SE (MRSE) (365) was 100%.

The mecA gene was detected in two methicillin-susceptible Staphylococcus aureus (MSSA) and one methicillin-susceptible S. epidermidis (MSSE) with a negative percent agreement (NPA) of 99.1% (221/223) and 99.2% (120/121), respectively. The PPA and NPA for vancomycin-resistant Enterococcus faecium (VRE) was 100%. The BC-GP panel demonstrated excellent performance and clinicians can confidently de-escalate antimicrobial therapy in the absence of mecA and vanA/B gene. The panel also identifies coagulase-negative staphylococci that are usually contaminants obtained from a patient's skin at the time of a blood draw, and that can enable clinicians to discontinue antibiotics if the patient is stable and the clinician is comfortable that an infection is not present.

Jennifer Dien Bard, PhD, D(ABMM), F(CCM), an associate professor and co-author of the study, said, “Deescalating to a more targeted antibiotic, such as cefazolin or oxacillin, is efficacious because it optimizes treatment for patients with a methicillin-susceptible Staphylococcus aureus (MSSA. A clinician would switch, in this case, from prescribing vancomycin, a broad-spectrum antibiotic. Traditional susceptibility testing, however, can take longer than is optimal, requiring about 20 to 24 hours to identify the pathogen and an additional 18 to 24 hours to test for susceptibility. That's when the process is straight forward and we don't have to do repeat testing for some reason.” The study was published on August 11, 2018, in the European Journal of Clinical Microbiology & Infectious Diseases.

Related Links:
Children’s Hospital Los Angeles

New
Gold Member
Syphilis Screening Test
VDRL Antigen MR
Automated Blood Typing System
IH-500 NEXT
New
Centrifuge
Centrifuge 5430/ 5430 R
New
Liquid Based Cytology Production Machine
LBP-4032

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.