Commercial System Effective for Cefiderocol Susceptibility Testing

By LabMedica International staff writers
Posted on 11 Jul 2019
Print article
Image: The Sensititre Complete Automated Antibiotic Susceptibility Testing (AST) System performs all susceptibility testing on a single platform utilizing the superior sensitivity of true MIC results (Photo courtesy of Thermo Fisher Scientific).
Image: The Sensititre Complete Automated Antibiotic Susceptibility Testing (AST) System performs all susceptibility testing on a single platform utilizing the superior sensitivity of true MIC results (Photo courtesy of Thermo Fisher Scientific).
The novel formulation of the cephalosporin antibiotic makes it very effective against gram-negative non-fastidious bacteria that are otherwise highly resistant to antibiotics, including carbapenem-resistant strains of Enterobacteriaceae and non-fermenters.

In microbiology, the minimum inhibitory concentration (MIC) is the lowest concentration of a chemical, usually a drug, which prevents visible growth of bacterium. MIC depends on the microorganism, the affected human being (in vivo only), and the antibiotic itself.

An international team of scientists working with Thermo Fisher Scientific (Cleveland, Ohio, USA) conducted a study that involved 374 recent clinical isolates, which included Escherichia coli, Klebsiella spp., Enterobacter spp., Citrobacter spp., Serratia marcescens, Pseudomonas aeruginosa, and Acinetobacter baumannii. One of the four study sites additionally used 147 Centers for Disease Control and Prevention challenge isolates. Three sites also used 11 reproducibility isolates, with three of these isolates being tested each day for three days. Finally, all four sites tested two quality control strains: E. coli ATCC 25922 and P. aeruginosa ATCC 27853.

The team tested a commercially prepared dried minimum inhibitory concentration (MIC) susceptibility system, the Thermo Fisher Scientific Sensititre, and demonstrated an equivalent level of performance compared with the Clinical & Laboratory Standards Institute (CLSI) M07/M100 and the International Organization for Standardization (ISO) 20776-1 reference broth microdilution (BMD) method when testing cefiderocol against Gram-negative non-fastidious organisms.

Overall agreement for the reproducibility (± 1 log2 dilution) concerning the most frequent (or modal) MIC value using automated and manual reading was 95.0% and 95.3%, respectively. The lowest agreement between the two test methods was 90.0% for Enterobacter spp., followed by 92.0% for Citrobacter spp. The strongest agreement was for P. aeruginosa (97.5%). The agreement among the four testing sites was high, at about 95%.

Thomas C. Lewis, BSc, a Research and Development Project Leader at Thermo Fisher Scientific, said, “The high level of agreement obtained by the Sensititre susceptibility system and the CLSI/ISO BMD method suggests that this is an acceptable method for susceptibility testing of cefiderocol. The results are available within 18 to 24 hours, versus several days for the broth. Plus, the testing materials can be kept on the laboratory shelf at room temperature before being used, which is a lot more convenient.” The study was presented at the Annual meeting of the American Society of Microbiology, held June 7-11, 2019, in Atlanta, GA, USA.

Related Links:
Thermo Fisher Scientific

Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Hepatitis B Virus Test
HBs Ab – ELISA
New
Urine Strips
11 Parameter Urine Strips

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.