D-Dimer Blood Test Detects Prosthetic Joint Infections as Accurately as Standard Tests

By LabMedica International staff writers
Posted on 13 Feb 2023
Print article
Image: D-dimer can help in making the difficult diagnosis of prosthetic joint infection (Photo courtesy of Pexels)
Image: D-dimer can help in making the difficult diagnosis of prosthetic joint infection (Photo courtesy of Pexels)

Periprosthetic joint infection (PJI) is a serious complication of failed total hip or knee replacement and among the primary causes of implant failure. Diagnosing PJI can be highly challenging because there is no single test that can claim to have 100% accuracy in determining or ruling out its presence. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR), which are two common markers of inflammation, are recommended as screening tests for patients suspected of having PJI. However, both these markers have limitations, such as a high rate of false-negative results when PJI is present. Plasma D-dimer, a test commonly used for certain blood clot-related disorders, is also a potentially useful marker of infection and has been validated for use in the diagnosis of PJI. However, some studies have raised concerns over the diagnostic performance of D-dimer testing for PJI, and its true accuracy is still unknown. Now, a new study suggests that the measurement of plasma D-dimer levels can provide useful information when making the difficult diagnosis of PJI.

In the new study, researchers at Thomas Jefferson University (Philadelphia, PA, USA) compared plasma D-dimer and other tests for the diagnosis of PJI. Over a four-year period, the study prospectively enrolled 502 patients undergoing revision knee or hip arthroplasty, irrespective of their surgical indication. All the patients underwent a blood draw just before their surgery to measure their levels of D-dimer, CRP, and ESR, and fibrinogen. After applying the 2018 International Consensus Meeting definition of PJI, the researchers found 23% of the patients had PJI. The four tests had "comparable accuracy" for the diagnosis of PJI. Sensitivity (ability to detect PJI when present) was 81.3% for D-dimer, 90.4% for CRP, 73.9% for ESR, and 74.7% for fibrinogen. On the other hand, specificity (correctly showing that PJI was not present) was 81.7% for D-dimer, 70.0% for CRP, 85.2% for ESR, and 75.4% for fibrinogen. For all four measures, the values were higher for patients who were shown to have PJI.

However, in some patient subgroups, D-dimer offered a diagnostic advantage. In a sub-analysis that excluded patients with certain health conditions associated with inflammation, the D-dimer test outperformed ESR, fibrinogen, and CRP in recognizing the presence of PJI. D-dimer also performed best in detecting PJI caused by slow-growing "indolent" organisms, with higher values for both sensitivity and specificity. Additionally, all the four tests showed a better diagnostic performance in patients with suspected PJI in the knee, as compared with PJI in the hip. The report is the largest prospective study evaluating the performance of different laboratory tests for suspected PJI and support D-dimer testing as a valuable tool for the often-difficult diagnosis of PJI. There is a need for further studies, and no universal diagnostic cutoff point can be determined due to known variations in D-dimer measurement, according to the researchers.

"We found that plasma D-dimer was noninferior to serum CRP and ESR in the diagnosis of PJI and may be a useful adjunct when screening patients undergoing revision total joint arthroplasty," said Javad Parvizi, MD, FRCS, and colleagues of Rothman Orthopedic Institute at Thomas Jefferson University.

Related Links:
Thomas Jefferson University

New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Centromere B Assay
Centromere B Test
New
Toxoplasma Gondii Immunoassay
Toxo IgM AccuBind ELISA Kit

Print article

Channels

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.