We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Placental Malaria Diagnosed In Poorly Processed Placental Tissue

By LabMedica International staff writers
Posted on 08 Jun 2016
Print article
Image: A photomicrograph of placental tissue revealing the presence of the malarial parasites. The blue arrows point to examples of red blood cells containing pigment and the black arrow points to an example of a pigment-containing histiocyte (Photo courtesy of Drucilla J Roberts, MD).
Image: A photomicrograph of placental tissue revealing the presence of the malarial parasites. The blue arrows point to examples of red blood cells containing pigment and the black arrow points to an example of a pigment-containing histiocyte (Photo courtesy of Drucilla J Roberts, MD).
Placental histopathology has been considered the gold standard for diagnosis of malaria during pregnancy; however, in under-resourced areas placental tissue is often improperly fixed and processed; the resulting formalin pigment is difficult to distinguish from malaria pigment.

It is often problematic to diagnose malaria in pregnant women because parasitized erythrocytes sequestered in the placenta are often absent from the peripheral circulation. Microscopy of peripheral and placental blood, polymerase chain reaction (PCR), and rapid diagnostic tests have been used but vary in sensitivity and specificity.

Scientists the University of North Carolina (Chapel Hill, NC, USA) and their international colleagues performed a prospective study and enrolled 182 adult women with healthy, singleton pregnancies less than 23 weeks gestational age. After delivery, a placental biopsy was collected from an incision at a healthy pericentric area of the placenta. Blood samples were collected from study participants zero to 33 days before delivery.

Real-time quantitative polymerase chain reaction (qPCR) was performed on DNA extracted from filter paper-dried blood spots using a high-throughput pooling strategy. Paraffin sections of approximately 5 µm were stained with Giemsa according to standard histologic protocols. The stained sections were examined by two blinded microscopists under light microscopy to assess parasitemia and malaria pigment. Immunohistochemistry (IHC) was using a monoclonal antibody to Plasmodium falciparum histidine-rich protein 2 (HRP2) was carried out on 5 mm thick, formalin-fixed, paraffin-embedded sections using an automated Bond Leica IHC stainer (Leica Microsystems, Bannockburn, IL, USA).

The sensitivity and specificity of individual tests were calculated using PCR or IHC as the reference standard as well as latent class analysis (LCA). The PCR (at time closest to delivery) was used as the gold standard. With PCR as the reference standard, all of the other tests had high specificities, but low sensitivities. The most sensitive other test was IHC, but it missed 50 % of the malaria infections diagnosed by PCR. The correlation between the two blinded microscopists was poor, as there was widespread formalin pigment. Using LCA, all of the tests had high specificities. The most sensitive test was IHC (67.7%), with PCR as second best (56.1%).

The authors concluded that since IHC can detect parasites when they sequester in the placenta but do not circulate, while PCR detects extremely low parasitemia, the combination of both methods might provide a means of detecting the greatest number of infections. Therefore PCR and/or IHC are suitable diagnostics when the presence of formalin pigment substantially compromises placental histopathology. The study was published on May 10, 2016, in the Malaria Journal.

Related Links:
University of North Carolina
Leica Microsystems
Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
Automated Blood Typing System
IH-500 NEXT
New
Toxoplasma Gondii Test
Toxo IgG ELISA Kit
New
Hepatitis B Virus Test
HBs Ab – ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.