Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Roche Diagnostics

Develops, manufactures, and markets a wide range of in vitro diagnostic systems, instruments, reagents, and tests read more Featured Products: More products

Download Mobile App




Blood Test Predicts Heart Attack Risk

By LabMedica International staff writers
Posted on 07 May 2014
Print article
Image: The Elecsys 2010 chemistry analyzer system (Photo courtesy of Roche).
Image: The Elecsys 2010 chemistry analyzer system (Photo courtesy of Roche).
High-sensitivity cardiac troponin T (hs-cTnT) is a relatively new biomarker used in the diagnosis of heart attack and is detectable in the blood several hours before older methods of measuring troponins.

Patients presenting to the emergency department with chest pain and an undetectable level of the blood biomarker hs-cTnT, and whose electrocardiography show no sign of restricted blood flow, have a minimal risk of heart attack within 30 days.

Scientists at the Karolinska University Hospital (Stockholm, Sweden) studied 14,636 patients reporting to a Swedish emergency department with chest pain over a two-year period from 2010 to 2012. They evaluated if an undetectable level of less than 5 ng/L of hs-cTnT, and an electrocardiogram (ECG) without signs of ischemia can rule out myocardial infarction in the emergency department. Nearly 9,000 patients with an undetectable level of the biomarker, or less than 5 ng/L, on initial testing, and whose ECGs showed no heart damage from decreased blood flow, were included in the study to examine the primary endpoint of heart attack within 30 days.

The hs-cTnT levels were analyzed using the Elecsys 2010 system (Roche Diagnostics GmbH, Mannheim, Germany). This method has a detection limit of 2 ng/L, a 99th-percentile cutoff point of 14 ng/L, and a coefficient of variation of less than 10% at 13 ng/L. Patients were categorized into three groups according to the first hs-cTnT level: less than 5 ng/L, 5 to 14 ng/L and greater than 14 ng/L.

During the 30 days of follow-up, 39 of the 8,907 patients were diagnosed with heart attack, and 15 of these patients showed no signs of damage on ECG. According to the scientists this means that only one in 594 patients who seek medical attention for chest pain, but have no signs of heart damage on an ECG and undetectable levels of hs-cTnT are actually at immediate risk of heart attack. The average age of patients in the study was 47, and 53% were women.

Nadia Bandstein, MD, the lead author of the investigation, said, “Despite our observations before the study, we were still surprised by the strength of our findings. Using this blood test along with an ECG, we will save about 500 to 1,000 admissions per year in our hospital alone, allowing us to use the beds for sicker patients.” The authors recommend that that further studies need to be done to assess the risk of heart attack among patients with slightly higher levels of hs-cTnT, 5 to14 ng/L. It will also be important to look at the prognosis for patients diagnosed with heart attack based on slight elevations of the biomarker. The study was presented at the American College of Cardiology's 63rd Annual Scientific Session, held March 29–31, 2014, in Washington DC (USA)

Related Links:

Karolinska University Hospital
Roche Diagnostics GmbH


Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Auto Clinical Chemistry Analyzer
cobas c 703
New
Coagulation Analyzer
CS-2400

Print article

Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Pathology

view channel
Image: The ready-to-use DUB enzyme assay kits accelerate routine DUB activity assays without compromising data quality (Photo courtesy of Adobe Stock)

Sensitive and Specific DUB Enzyme Assay Kits Require Minimal Setup Without Substrate Preparation

Ubiquitination and deubiquitination are two important physiological processes in the ubiquitin-proteasome system, responsible for protein degradation in cells. Deubiquitinating (DUB) enzymes contain around... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.