We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Serum Biomarkers Improve Preeclampsia Screening

By LabMedica International staff writers
Posted on 31 May 2018
Print article
Image: The DELFIA Xpress immunoassay analyzer for prenatal screening (Photo courtesy of PerkinElmer).
Image: The DELFIA Xpress immunoassay analyzer for prenatal screening (Photo courtesy of PerkinElmer).
Preeclampsia (PE), which complicates 2% to 3% of pregnancies, is a major cause of mortality and morbidity for the mother and perinatal death and impairment for the baby.

A screening method for predicting preeclampsia based on the mother’s risk factors and biomarker measurements outperforms a standard method based only on maternal characteristics and medical history.

Scientists at King's College Hospital (London, UK) and their colleagues carried out a prospective multicenter study screening program for preeclampsia (SPREE) in seven National Health Service maternity hospitals in England, of women recruited between April and December 2016. The study involved 16,747 women between 11 and 13 weeks’ gestation who were assessed. The new screening method being evaluated in SPREE included not only maternal characteristics but also measurement of different combinations of mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI), serum placental growth factor (PlGF), and serum pregnancy-associated plasma protein-A (PAPP-A).

Maternal serum concentrations of PAPP‐A and PlGF were measured using one of two automated devices: DELFIA Xpress analyzer or the BRAHMS KRYPTOR analyzer. In all, 2.8% of participants developed preeclampsia; just 0.8% developed preterm preeclampsia, defined as requiring delivery before 37 weeks. The standard recommended method screened positive for 30.4% and 40.8% of all preeclampsia and preterm preeclampsia cases, respectively. In contrast, the new method combining maternal characteristics, MAP, and PAPP-A screened positive for 42.5% of all preeclampsia cases. Including PlGF and UtA-PI screened positive for 82.4% of all preterm preeclampsia cases.

The authors concluded that the performance of screening is substantially improved by a method combining maternal factors with biomarkers. Liona Poon, MD, a clinical senior lecturer and co-author of the study, said, “The SPREE study has provided definitive proof to support risk-based screening for preterm-preeclampsia using various biomarkers. It is now time to revise the professional guidelines and to move away from using a checklist-based method for screening.” The study was published originally published online on March 14, 2018, in the journal Ultrasound in Obstetrics Gynecology.

Related Links:
King's College Hospital

New
Gold Member
Human Chorionic Gonadotropin Test
hCG Quantitative - R012
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Pipet Controller
Stripettor Pro
New
Malondialdehyde HPLC Test
Malondialdehyde in Serum/Plasma – HPLC

Print article

Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Pathology

view channel
Image: The ready-to-use DUB enzyme assay kits accelerate routine DUB activity assays without compromising data quality (Photo courtesy of Adobe Stock)

Sensitive and Specific DUB Enzyme Assay Kits Require Minimal Setup Without Substrate Preparation

Ubiquitination and deubiquitination are two important physiological processes in the ubiquitin-proteasome system, responsible for protein degradation in cells. Deubiquitinating (DUB) enzymes contain around... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.