Highly Multiplexed Cell Surface Protein Analyzed Via Flow Cytometry

By LabMedica International staff writers
Posted on 06 Oct 2021
Modern immunologic studies increasingly requires high-dimensional analyses to understand the complex milieu of cell types that comprise the tissue microenvironments of disease. One of the cornerstones of immunology has been the detailed phenotypic classification of the cellular populations of the immune system.

Modern flow cytometric approaches exemplify this by using panels of multiple fluorochrome-conjugated (conventional flow cytometry) or metal-conjugated (mass cytometry) antibodies to measure protein expression profiles of individual cells with high cell throughput to capture and analyze both common and rare cell populations.

Clinical Scientists at the Fred Hutchinson Cancer Institute (Seattle, WA, USA) developed a workflow that enables highly multiplexed analysis of cell surface proteins using conventional flow cytometry. The method uses machine learning combined with data from overlapping flow cytometry assay panels to determine the co-expression patterns of hundreds of cell surface markers across millions of single cells.

The approach, named Infinity Flow, uses traditional flow cytometry as opposed to newer technologies like mass cytometry; it offers a potentially more accessible and less expensive route for single-cell proteomic studies. The method consists of two steps. First, the scientists stain all the cells in an experiment with antibodies to a small number of proteins. This is called the "backbone" panel and typically consists of around the 20 analytes that can be multiplexed using a conventional flow cytometer.

The scientists then subdivide the sample into a series of wells, each containing one of the additional antibodies to the proteins they are interested in. For instance, if the investigator want to look at another 200 proteins beyond those covered in the backbone panel, they would subdivide their sample into 200 different wells, each of which would contain an antibody against one of those 200 proteins. They then analyze each well of samples using flow cytometry, the BD Fortessa X-20 cytometer (BD Biosciences, Franklin Lakes, NJ, USA) allowing them to collect for each cell expression data on all of the "backbone" proteins along with data on the one additional protein designated for that sample well. With this data, the Infinity Flow software is able to predict for every cell being analyzed the expression levels of the 200 proteins of interest.

The team found that when they used a backbone panel of proteins common to all T cells, they were unable to impute protein expression levels for particular T-cell types due to the fact that, based on the backbone signature, all T cells looked the same. This, they noted, indicates that tailoring backbone panels to the samples and cell populations of interest can improve the assay's performance. They also found that the method was best able to impute expression levels for proteins that exhibited multimodal expression patterns and were highly or commonly expressed. In an evaluation of an Infinity Flow assay detailed in the study, they determined that they were able to generate "meaningful imputed signal" for 155 of 252 markers measured.

Mark Headley, PhD, an assistant professor in immunology and a leading author of the study, said, “Infinity Flow costs scale more slowly. We can measure 10 million, 20 million, 30 million cells at the same cost. It doesn't cost you more to do the assay the more cells you do.” The study was published on September 22, 2021 in the journal Science Advances.

Related Links:
Fred Hutchinson Cancer Institute
BD Biosciences




Gold Member
Veterinary Hematology Analyzer
Exigo H400
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Anti-HHV-6 IgM Assay
anti-HHV-6 IgM ELISA (semiquant.)
New
Respiratory Bacterial Panel
Real Respiratory Bacterial Panel 2
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.