We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Sentinel Diagnostics

Sentinel Diagnostics develops and manufactures in-vitro diagnostic medical devices for routine analysis and specific ... read more Featured Products: More products

Download Mobile App




Fecal Immunochemical Test for Hemoglobin Evaluated on Automated System

By LabMedica International staff writers
Posted on 25 Jan 2022
Colorectal cancer (CRC) is the third most common cancer in men and women and has the second most mortality rate worldwide. Most of the new CRC cases are found in patients presenting with symptoms in primary health care, such as changes in bowel habit and red blood in the feces.

Fecal immunochemical tests (FIT) for detection and quantification of detection of hemoglobin in feces (f-Hb) are well established and have replaced traditional guaiac-based tests in national screening programmes in most European countries. Several quantitative immunochemical tests are available, however only a few tests are available on high throughput automated analyzers.

Medical Biochemists and their colleagues at the Aalesund Hospital (Aalesund, Norway) evaluated, as part of a study, 163 symptomatic patients over 18 years referred to colonoscopy for assessment of lower abdominal symptoms. The study was performed between January 2020 and February 2021. Invitation to colonoscopy together with a collection device and detailed instructions for sampling of feces was sent by mail 2-4 weeks before meeting for colonoscopy. Patients were asked to collect a fecal sample 3-7 days before colonoscopy. There were no dietary restrictions before sampling.

Fecal samples were collected in FOB Gold sample tubes (Sysmex Norge, Oslo, Norway). Samples were analyzed with the SENTIFIT-FOB Gold test (Sentinel Diagnostics, Milano, Italy), which is a latex agglutination immunoturbidimetric assay for quantitation of hemoglobin in feces. The assay was applied on an open channel on the Roche Cobas 8000 c702 automated analyzer (Roche Diagnostics, Oslo, Norway). The time of analysis on the Roche Cobas 8000 system was 10 minutes. Diagnostic accuracy and optimal cutoff of the FIT-assay were determined by comparing fecal hemoglobin (f-Hb) concentrations with colonoscopy findings as reference.

The investigators reported that the SENTIFIT-FOB Gold assay showed an imprecision with a total coefficient of variation (CV%) <10% at all concentrations of quality control material and patient sample pools analyzed. At average f-Hb concentrations of 24 ± 0.8 μg/g and 58 ± 2.3 μg/g in patient sample pools the within-run imprecision (repeatability) was 3.4% and 3.9%, respectively. The accuracy of the assay was performed by comparison of the mean quality control sample hemoglobin concentration with the target specified by the manufacturer. The deviation of the mean from the specified target concentration was <4% in both control samples. The Limit of blank (LoB) and Limit of detection (LoD) were estimated to 1 μg/g and 2 μg/g, respectively when using buffer spiked with standard. Using a real patient sample with low f-Hb concentration the LoD was 2 μg/g.

The authors concluded that the SENTIFIT-FOB Gold assay for quantification of hemoglobin in feces applied on the automated Roche Cobas 8000 analyzer shows adequate analytical and clinical performance which agrees well with the performance of the assay on the SENTIFIT-270 analyzer. This enables effective and efficient use of a quantitative FIT on a high-throughput analyzer in large routine clinical chemistry laboratories. In patients presenting with lower abdominal symptoms a cutoff of 10 μg/g seems to be optimal for referral to secondary care and provides a reliable prediction of the absence of CRC and advanced adenoma. The study was published on January 15, 2022 in the journal Practical Laboratory Medicine.

Related Links:
Aalesund Hospital
Sysmex Norge
Sentinel Diagnostics
Roche Diagnostics



Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Coagulation Analyzer
CS-2400
New
Troponin I Test
Quidel Triage Troponin I Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The experimental blood test accurately indicates severity and predicts potential recovery from spinal cord injury (Photo courtesy of 123RF)

Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury

The National Institutes of Health estimates that 18,000 individuals in the United States sustain spinal cord injuries (SCIs) annually, resulting in a staggering financial burden of over USD 9.... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: Tumor-associated macrophages visualized using the Multiomic LS Assay (Photo courtesy of ACD)

Leica Biosystems and Bio-Techne Expand Spatial Multiomic Collaboration

Bio-Techne Corporation (Minneapolis, MN, USA) has expanded the longstanding partnership between its spatial biology brand, Advanced Cell Diagnostics (ACD, Newark, CA, USA), and Leica Biosystems (Nussloch,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.