Collection Tubes Influence Targeted Metabolomics Studies

By LabMedica International staff writers
Posted on 08 Oct 2018
Print article
Image: The QTRAP 6500 Q-Trap mass spectrometer (MS) (Photo courtesy of Sciex).
Image: The QTRAP 6500 Q-Trap mass spectrometer (MS) (Photo courtesy of Sciex).
Plasma and serum are the most widely used matrices in clinical studies. However, some variability in absolute concentrations of metabolites are likely to be observed in these collection tubes matrices.

Selecting the correct matrix for biochemical analysis is of paramount importance in order to avoid improper diagnosis. Blood collection tubes are often an under-recognized variable in the pre-analytical phase of clinical studies, and it is thus important to evaluate the influences of these matrices during metabolomics analysis.

An international team of scientists working with the Institute for Biomedicine (Eurac Research, Bolzano, Italy) enrolled a total of 40 healthy independent individuals who were selected with age lower than 35 years and assigned to the “young” group. The other 40 healthy independent subjects were selected with age higher than 60 years and assigned to the “elderly” group. Blood was collected at the recruitment center after overnight fasting, and taken in the early morning within a short time interval.

Serum, EDTA and Citrate Vacuette vacutainer collection tubes were provided by Greiner Bio-One. For liquid chromatography mass spectrometry, targeted analysis was performed using the Biocrates AbsoluteIDQ p180 kit with an ultra-high-performance liquid chromatography (UHPLC) coupled to a Q-Trap mass spectrometer (MS).

The team analyzed 189 metabolites using the same protocol for quantitative targeted metabolomics. The concentration levels were higher in serum than citrate and EDTA, in particular for amino acids and biogenic amines. For amino acids, the average value of the relative difference was 7% higher in serum than EDTA and 6% higher in serum than citrate. For biogenic amines the average value of the relative difference was 11% higher in serum than EDTA and 15% higher in serum than citrate. The investigators also demonstrated that blank EDTA vacutainer tubes contain a significant amount of sarcosine. Finally, they compared the metabolome of young people against elderly subjects and found that the highest number of metabolites significantly changing with age was detected in serum.

The authors concluded that serum samples provide higher sensitivity for biomarker discovery studies. Due to the presence of spurious amount of sarcosine in vacutainer EDTA tubes, plasma EDTA is not suitable for studies requiring accurate quantification of sarcosine. The study was published online on August 13, 2018, in the journal Clinica Chimica Acta.

Related Links:
Institute for Biomedicine

Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
HIV-1 Test
HIV-1 Real Time RT-PCR Kit
New
Centrifuge
Hematocrit Centrifuge 7511M4

Print article

Channels

Molecular Diagnostics

view channel
Image: Researcher Kanta Horie places a sample in a mass spectrometer that measures protein levels in blood plasma and other fluids (Photo courtesy of WashU Medicine)

Highly Accurate Blood Test Diagnoses Alzheimer’s and Measures Dementia Progression

Several blood tests are currently available to assist doctors in diagnosing Alzheimer's disease in individuals experiencing cognitive symptoms. However, these tests do not provide insights into the clinical... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.