We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Urinary Hydration Markers Tested for Storage Condition Validity

By LabMedica International staff writers
Posted on 27 Aug 2019
Print article
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Fluid balance is an aspect of the homeostasis of organisms in which the amount of water in the organism needs to be controlled, via osmoregulation and behavior, such that the concentrations of electrolytes in the various body fluids are kept within healthy ranges.

The human kidneys will normally adjust to varying levels of water intake. The kidneys will require time to adjust to the new water intake level. This can cause someone who drinks a lot of water to become dehydrated more easily than someone who routinely drinks less. Analysis of urine specimens is widely utilized to determine day-to-day hydration status in individuals as well as for other markers of health.

Scientists at the University of North Carolina at Greensboro (Greensboro, NC, USA) enrolled eight males and 13 females (mean ± SD; age, 24 ± 5 years; body mass, 68.9 ± 24.2 kg; height, 160.2 ± 32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers. Participants provided a 24 hour urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7 °C and 22 °C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed, SS) or the manufacturers cap plus laboratory wrapping film (double sealed, DS).

Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG), and urine color (UCOL). UOSMO was stable at 7 °C for two days and three days for single sealed and double sealed containers, respectively. UOSMO was determined via freezing point depression with a 3320 osmometer. USG was measured using an optical refractometer that was accurate to ±0.001 AU and had a resolution of 0.0001. UCOL was measured by comparing each urine sample to an 8-point urine color chart where the sample was held against a white background in a well-lit room.

The team reported that USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22 °C. UCOL measures were maintained for up to three days in all storage methods. For refrigerated samples, UOSMO measures for samples stored in SS containers became significantly elevated three days following baseline measures, whereas UOSMO measures for samples stored in DS containers became significantly elevated seven days following baseline measures. Conversely to UOSMO, USG measures were significantly elevated in SS and DS samples stored at 7 °C beginning one day following baseline measures, compared to SS and DS samples stored at 20 °C.

The authors concluded that to achieve optimal results, it is recommended that 24-hour urine samples are assessed immediately for the respective hydration markers being analyzed. If immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24-hour urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 hours. The study was published on August 5, 2019, in the journal PLOS ONE.

Related Links:
University of North Carolina at Greensboro

Gold Member
Flocked Fiber Swabs
Puritan® Patented HydraFlock®
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
Total Hemoglobin Monitoring System
GREENCARE Hb
New
Centrifuge
Hematocrit Centrifuge 7511M4

Print article

Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Pathology

view channel
Image: The ready-to-use DUB enzyme assay kits accelerate routine DUB activity assays without compromising data quality (Photo courtesy of Adobe Stock)

Sensitive and Specific DUB Enzyme Assay Kits Require Minimal Setup Without Substrate Preparation

Ubiquitination and deubiquitination are two important physiological processes in the ubiquitin-proteasome system, responsible for protein degradation in cells. Deubiquitinating (DUB) enzymes contain around... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.