We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

BODITECH

Boditech Med Inc. develops products for in-vitro diagnostics and diagnostic reagents. Its products include automatic ... read more Featured Products: More products

Download Mobile App




Biomarkers Evaluated for Severity of Diabetic Kidney Disease

By LabMedica International staff writers
Posted on 24 Aug 2020
Print article
Image: iCHROMA is an automatic or semiautomatic in-vitro diagnostic device that measures via cartridges the concentration of analytes, contained in blood, urine, or other samples, in quantitative or semi-quantitative ways (Photo courtesy of Boditech Med Inc).
Image: iCHROMA is an automatic or semiautomatic in-vitro diagnostic device that measures via cartridges the concentration of analytes, contained in blood, urine, or other samples, in quantitative or semi-quantitative ways (Photo courtesy of Boditech Med Inc).
Type 2 diabetic mellitus (T2DM) is a chronic metabolic disorder with multiple complications, including diabetic retinopathy, diabetic neuropathy, diabetic kidney disease (DKD) as well as cardiovascular diseases. T2DM is related to an exacerbated systematic inflammation.

Among all plasma inflammatory biomarkers, erythrocyte sedimentation rate (ESR) and high-sensitivity C-reactive protein (hsCRP) are the mostly commonly used laboratory tests for identifying systematic inflammation. Both ESR and hsCRP are important markers in various inflammation-related diseases.

A team of endocrinologists at Huashan Hospital (Shanghai, China) conducted a cross-sectional study in 1,210 patients with T2DM, among whom 265 had DKD. The severity of DKD was assessed by estimated-glomerular filtration rate (eGFR) and urinary albumin creatinine ratio (ACR). The relationship between ESR, hsCRP and DKD was analyzed by multivariate logistic analysis. The relationship between ESR and eGFR, ESR or ACR was analyzed by multivariate linear regression.

Fasting blood sample was collected to measure fasting plasma glucose (FBG), glycated hemoglobin (HbA1c), hsCRP, serum albumin (ALB), globulin (GLB), total cholesterol (TC), triglyceride (TG), high-density lipoprotein cholesterol (HDL) and low-density lipoprotein cholesterol (LDL), serum creatinine (SCr), and ESR. ESR was measured using ESR-30 fully automatic dynamic analyzer (Xunda Medical Instrument Co., Ltd., Shanghai, China). FBG, TC, TG, HDL, LDL, ALB, total protein, SCr was quantified by Beckman AU5800 (Beckman Coulter Inc., Brea, CA, USA). HsCRP was detected by iCHROMA reader (Boditech Med Inc, Chungcheon-si, South Korea).

The scientists reported that ESR (23.0 mm/h [12.0 ~ 41.5] versus 12.0 mm/h [7.0 ~ 22.0], and hsCRP (3.60 mg/L [2.20 ~ 7.65] versus 2.90 mg/L [1.80 ~ 5.60],) values were significantly higher in patients with DKD than those without. Patients with higher ESR or hsCRP had lower eGFR and higher urinary albumin creatinine ratio (ACR). After adjusted for gender, age, hemoglobin, plasma proteins, HbA1c, lipid profiles, and the usage of renin-angiotensin system inhibitors, ESR but not hsCRP was independently associated with the rate and severity of DKD in patients with T2DM.

The authors concluded that their study underlined the role of inflammation in DKD. The study found that, both ESR and hsCRP correlated with DKD in T2DM, of which ESR was an independent risk factor for DKD and positively associated with severity of DKD. The study was published on July 13, 2020 in the journal BMC Endocrine Disorders



Gold Member
Turnkey Packaging Solution
HLX
Automated Blood Typing System
IH-500 NEXT
New
Malaria Rapid Test
OnSite Malaria Pf/Pan Ag Rapid Test
New
Vibrio Cholerae O1/O139 Rapid Test
StrongStep Vibrio Cholerae O1/O139 Antigen Combo Rapid Test

Print article

Channels

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.